Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect X13 from the PCB
Disconnect the lead from the diverter valve motor
Disconnect the lead from the diverter valve motor
Measurement:
Measure the resistance of each of the leads in the harness from the PCB to the diverter valve.
Expect Zero Resistance on each test
Red to Red(R)
Black to Black(B)
White to White(W)
Expect Zero Resistance on each test
Red to Red(R)
Black to Black(B)
White to White(W)

Isolate as per TOPs P4
and refit as necessary