Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the black wires from the overheat thermostat
Measurement:
Measure the resistance between one of overheat thermostat terminals and the screw securing it (it does not matter which terminal or screw).
Expect open circuit (O.L).
Is the resistance measured as expected?
Expect open circuit (O.L).
Is the resistance measured as expected?

Isolate as per TOPs P4
and refit as necessary