Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
Selector switch to DHW position
CH temperature selector to Min
DHW temperature selector to Max
CH temperature selector to Min
DHW temperature selector to Max
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage at the modulating solenoid and a suitable neutral.
Approximately 15-20 volts should be present.
Approximately 15-20 volts should be present.

Isolate as per TOPs P4
and refit as necessary