Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Selector switch to DHW position
DHW temperature selector to Max
Selector switch to DHW position
DHW temperature selector to Max
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure voltage at connection 3 (brown wire) and connection 4 (blue wire) on connector CN7 on the main PCB.
Note: On some PCB's the connector will be labelled as CON4 not CN7, however the test points and the colours of the wires stated remain the same.
Note: On some PCB's the connector will be labelled as CON4 not CN7, however the test points and the colours of the wires stated remain the same.

Isolate as per TOPs P4
and refit as necessary