Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Gain access to PCB (use Insulation Mat as required)
Selector switch to DHW position
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure voltage across connection 2 (orange wire) on connector CN7 on the main PCB and a suitable neutral.
Note: On some PCB's the connector will be labelled as CON4 not CN7, however the test points and the colours of the wires stated remain the same.