Set Appliance State:
Mains Reset Switch OFF
Isolate Mains Power to appliance as per TOPs P4
Remove Clip and remove diverter valve head from body
Disconnect electrical connector from valve actuator
Remove Clip and remove diverter valve head from body
Disconnect electrical connector from valve actuator
Measurement:
At exposed connectors Measure resistances from central connection to each of the outer connections.
Expect 8.5 kOhms or greater on both connections
Note:
Take this opportunity to check for any signs of water ingress into valve actuator as this will also cause fuse to blow intermittently.
Expect 8.5 kOhms or greater on both connections
Note:
Take this opportunity to check for any signs of water ingress into valve actuator as this will also cause fuse to blow intermittently.

Isolate as per TOPs P4
and refit as necessary