Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Measurement:
Visually inspect the burner link connector (blue on connector X100) ensure it is pushed fully home.
Measure the resistance between the two terminals of the link.
Expect short circuit.
Note:
The link does not have to be removed from the PCB to carry out the resistance check.
Measure the resistance between the two terminals of the link.
Expect short circuit.
Note:
The link does not have to be removed from the PCB to carry out the resistance check.

Isolate as per TOPs P4
and refit as necessary