Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to run.
Measure the DC voltage between pin 3 (Black) on connector X20 and a suitable earth.
Expected voltage approximately 5.6 Vdc.
Note:
Each pin on the PCB connector is numbered.