Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X18 from the PCB
Measurement:
Test 1:
Measure the resistance between the Blue and Black wires at X18.
Expect approximately 121 ohms.
Test 2:
Measure the resistance between the Brown and White wires at X18.
Expect approximately 57 ohms.
Test 3:
Measure the resistance between the Brown, Blue, Black and White wires to Earth.
Expect open circuit on each test.
Measure the resistance between the Blue and Black wires at X18.
Expect approximately 121 ohms.
Test 2:
Measure the resistance between the Brown and White wires at X18.
Expect approximately 57 ohms.
Test 3:
Measure the resistance between the Brown, Blue, Black and White wires to Earth.
Expect open circuit on each test.

Isolate as per TOPs P4
and refit as necessary