Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use Insulation Mat as required)
Main On/Off Control in the On position
Heating Control to Heating & Hot Water
CH Temperature Control to Maximum
Remove plug X25 from Relay Board
Remove Yellow plug X12 from Motherboard and make safe
Main On/Off Control in the On position
Heating Control to Heating & Hot Water
CH Temperature Control to Maximum
Remove plug X25 from Relay Board
Remove Yellow plug X12 from Motherboard and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
If a fault is displayed press boiler 'Reset' button.
Measure Mains Voltage across X25 on Relay Board.
Measure Mains Voltage across X25 on Relay Board.

Isolate as per TOPs P4
and refit as necessary