Set Appliance State:
Ensure NO demands
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Navigate to d.0 in the diagnostic codes menu and check its value - click HERE for guidance on how to access the diagnostic codes.
Is the value set to a kW output suitable for the CH system that the appliance is attached to?
Note:
The kW output can only set between certain values depending on the appliance. See the table below for the range of outputs for each appliance.
Is the value set to a kW output suitable for the CH system that the appliance is attached to?
Note:
The kW output can only set between certain values depending on the appliance. See the table below for the range of outputs for each appliance.
| Appliance | Heating Output (kW) |
| ecoMAX 824/2 E | 11 to 19 | ecoMAX 828/2 E | 13 to 23 | ecoMAX 835 E | 10 to 27 |