Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove the spark electrode assembly

Measurement:

Measure the resistance of the spark electrode from end to end.
Expect continuity/zero resistance.
Measure the spark gap between the electrodes which should be approximately 5mm.
Check the electrode has not warped or distorted by checking the measurement to the tip from a flat surface is approximately 12mm as shown and that it looks like the image.
Also thoroughly inspect the ignition electrode for good general condition and that the ceramic is not cracked.