Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Remove electrical connector from fan assembly and make safe
Remove electrical connector from fan assembly and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Reset appliance if required (Press reset button once then release)
Measure the DC voltage between pin 17 on connector X2 and a suitable earth.
Expect approximately 21vdc.
Is the voltage measured as expected?
Measure the DC voltage between pin 17 on connector X2 and a suitable earth.
Expect approximately 21vdc.
Is the voltage measured as expected?

Isolate as per TOPs P4
and refit as necessary