Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Measurement:
Test 1.
Set thermostat to OFF position.
Measure the resistance across connection 24 (yellow lead) and connection 25 (yellow lead) on the control module.
Resistance should be open circuit.
Test 2.
Set thermostat to MIN position.
Measure the resistance across connection 24 (yellow lead) and connection 25 (yellow lead) on the control module.
Resistance should be closed circuit.
Set thermostat to OFF position.
Measure the resistance across connection 24 (yellow lead) and connection 25 (yellow lead) on the control module.
Resistance should be open circuit.
Test 2.
Set thermostat to MIN position.
Measure the resistance across connection 24 (yellow lead) and connection 25 (yellow lead) on the control module.
Resistance should be closed circuit.