Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove the leads from the air heater switch
Remove the leads from the air heater switch
Measurement:
Test 1.
Set the air heater switch to timed.
Measure the resistance across the top (white lead) and the middle (pink lead) terminals.
Resistance should be closed circuit.
Test 2. Set the air heater switch to continuous.
Measure the resistance across the middle (pink lead) and the bottom (grey lead) terminals.
Resistance should be closed circuit.
Note.
The lead colours are shown for information only.
Set the air heater switch to timed.
Measure the resistance across the top (white lead) and the middle (pink lead) terminals.
Resistance should be closed circuit.
Test 2. Set the air heater switch to continuous.
Measure the resistance across the middle (pink lead) and the bottom (grey lead) terminals.
Resistance should be closed circuit.
Note.
The lead colours are shown for information only.

Isolate as per TOPs P4
and refit as necessary