Set Appliance State:

User Control to Off Position
Set Multimeter to DC Volts Set meter to measure DC Volts
Isolate Mains Power to appliance as per TOPs P4
Gain Access to PCB
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure voltage across connection 1 (red lead) and connection 12 (yellow lead) on connector marked CN3 Display on the main PCB.
Expected voltage between 22 and 30 volts DC.