Set Appliance State:
Mains Power Off
User Control to Off Position
Ensure DHW is calling for heat
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
User control switch to ON position.
Allow fan to run and ignition sequence to commence.
Observe meter test dial. Does the test dial show that gas is passing signifying the gas valve has opened?
Note:
No other appliances should be in use during this test. There will be 5 ignition attempts at approximately 35 second intervals in which the gas valve should open.
Allow fan to run and ignition sequence to commence.
Observe meter test dial. Does the test dial show that gas is passing signifying the gas valve has opened?
Note:
No other appliances should be in use during this test. There will be 5 ignition attempts at approximately 35 second intervals in which the gas valve should open.