Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Appliance drained and discharged
Remove connector 20 (Pump) from the PCB and make safe
Remove the diverter valve from the left side hydraulic block
Remove connector 20 (Pump) from the PCB and make safe
Remove the diverter valve from the left side hydraulic block
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Observe the diverter valve movement.
The diverter valve initially powers all the way in, it will then power fully out, protruding approximately 11mm as per the photo below.
Repeat test as required.
The diverter valve initially powers all the way in, it will then power fully out, protruding approximately 11mm as per the photo below.
Repeat test as required.
Isolate as per TOPs P4
and refit as necessary