Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the leads from the spark generator
Measurement:
Measure the resistance between terminals 2 and 3 on the spark generator.
Expected resistance approximately 640 Ohms.
Note.
The terminals on the spark generator will be numbered.
Expected resistance approximately 640 Ohms.
Note.
The terminals on the spark generator will be numbered.

Isolate as per TOPs P4
and refit as necessary