Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect leads from the APS
Connect the air pressure switch charge test kit to P1 (+ve) on the APS
Note the operating pressure which is indicated on APS
Connect the air pressure switch charge test kit to P1 (+ve) on the APS
Note the operating pressure which is indicated on APS
Measurement:
Increase the pressure via the syringe to that indicated on the APS.
Measure the resistance between terminals 1 and 3.
Expect continuity / zero resistance.
Note.
1. 100 Pascals = 1mbar / 50 Pascals = 0.5mb.
2. If continuity is not obtained, it is permissible to increase the pressure by 50%
Measure the resistance between terminals 1 and 3.
Expect continuity / zero resistance.
Note.
1. 100 Pascals = 1mbar / 50 Pascals = 0.5mb.
2. If continuity is not obtained, it is permissible to increase the pressure by 50%

Isolate as per TOPs P4
and refit as necessary