Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Rotate the CH temperature control knob to the OFF position
(This will allow you to see the current system pressure)
Measure the DC voltage between pin 1
and pin 2 on connector X9.
The voltage measured will vary according to the system pressure (refer to the pressure on the display) but should conform approximately to the table below;
(This will allow you to see the current system pressure)
Measure the DC voltage between pin 1
and pin 2 on connector X9.
The voltage measured will vary according to the system pressure (refer to the pressure on the display) but should conform approximately to the table below;

Isolate as per TOPs P4
and refit as necessary