Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove electrical connector from gas valve
Measurement:
Test 1.
Measure for resistance across the outer terminals of the gas valve.
Expected resistance approximately 4.2 KOhms.
Test 2.
Measure for resistance across one of the outer terminals to the center terminal of the gas valve.
Expected resistance greater than 1 MOhm.
A reading of O.L is acceptable as this is greater than 1 MOhm.
Note.
Ensure a good connection is made or misdiagnosis will occur.
Measure for resistance across the outer terminals of the gas valve.
Expected resistance approximately 4.2 KOhms.
Test 2.
Measure for resistance across one of the outer terminals to the center terminal of the gas valve.
Expected resistance greater than 1 MOhm.
A reading of O.L is acceptable as this is greater than 1 MOhm.
Note.
Ensure a good connection is made or misdiagnosis will occur.

Isolate as per TOPs P4
and refit as necessary