Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove functional case door
Remove the orange leads from the sensor
Remove functional case door
Remove the orange leads from the sensor
Measurement:
Measure resistance across the terminals of the sensor.
The resistance measured will depend on boiler temperature, the higher the temperature the lower the resistance.
Resistance should be approximately:
14.0 kOhms at room temperature,
7.5 kOhms at 30 degrees C,
2.0 kOhms at 60 degrees C.
The resistance measured will depend on boiler temperature, the higher the temperature the lower the resistance.
Resistance should be approximately:
14.0 kOhms at room temperature,
7.5 kOhms at 30 degrees C,
2.0 kOhms at 60 degrees C.

Isolate as per TOPs P4
and refit as necessary