Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Hinge down the PCB housing
Remove 8 way connector from PCB
Remove 8 way connector from PCB
Measurement:
Measure resistance across the two resistors fitted to the low voltage harness.
Resistance across the clear resistor
should be approximately 36kOhms.
Resistance across the blue resistor
should be approximately 18kOhms.
Resistance across the clear resistor
should be approximately 36kOhms.
Resistance across the blue resistor
should be approximately 18kOhms.

Isolate as per TOPs P4
and refit as necessary