Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Observation:
Test 1.
Break the lead at the spade connector to the condensate trap.
Mains Power On
Does the appliance ignite and establish?
Reconnect lead to condensate trap.
Test 2.
Break the lead at the 6 way connector to the condensate pump.
Mains Power On
Does the appliance ignite and establish?
Break the lead at the spade connector to the condensate trap.
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Does the appliance ignite and establish?
| Isolate Mains Power to appliance as per TOP's P4 |
Test 2.
Break the lead at the 6 way connector to the condensate pump.
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Does the appliance ignite and establish?