Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
CH Demand
Selector Switch to Hot Water and Heating
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance as necessary.
Using shrouded probes measure the voltage across
terminals at X501 and X500 on the PCB
Expect approx. 70 VAC before the flame is present.
Then when the flame lights the voltage should drop to approx. 59 VAC.