Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X11 from the PCB
Measurement:
Test 1: Measure resistance between the spark generator neutral (marked 10.2 on X11) and live (marked 10.1 on X10).
Expect greater than 1M Ohm.
Disconnect connector X10 from the PCB.
Test 2: Measure the resistance between the spark generator live (marked 10.1 on X10) and a suitable earth point.
Expect greater than 1M Ohm.
Test 3:Measure the resistance between the spark generator neutral (marked 10.2 on X11) and a suitable earth point.
Expect greater than 1M Ohm.
Expect greater than 1M Ohm.
Disconnect connector X10 from the PCB.
Test 2: Measure the resistance between the spark generator live (marked 10.1 on X10) and a suitable earth point.
Expect greater than 1M Ohm.
Test 3:Measure the resistance between the spark generator neutral (marked 10.2 on X11) and a suitable earth point.
Expect greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary