Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
POTTERTON POWERMAX HE INTEGRAL PROGRAMMER
WARNING - IMPORTA
SYSTEM CHECKS
PLEASE ENSURE THE FOLLOWING SYSTEM CHECKS ARE COMPLETED
POTTERTON POWERMAX HE INTEGRAL PROGRAMMER
{ISOLATEMAINSPOWER}<
FAN RUNS
DHW TEMPERATURE SELECTOR TO MAXIMUM POSITION
CH DEMAND
ENSURE DHW IS SATISFIED I.E. STORAGE CYLINDER UP TO TEMPERATURE
FAULT A02 A03 A04 E03 - OVERHEAT
OUTSIDE MODEL
FAULT A15 - PRESSURE SENSOR
OUTSIDE MODEL
FAULT E07 / E08 - DHW SENSOR
OUTSIDE MODEL
FAULT E04 / E06 - FLOW SENSOR
OUTSIDE MODEL
FAULT E21 - REVERSE POLARITY
OUTSIDE MODEL
FAULT E22 - INCORRECT FREQUENCY
OUTSIDE MODEL
FAULT E29 - FAULT ON J11 / PRESSURE SENSOR
OUTSIDE MODEL
FAULT E40 / E41 - RETURN SENSOR
OUTSIDE MODEL
FAULT A05 / E42 - SAFETY RELAY FAILURE / INTERNAL ERROR
OUTSIDE MODEL
FAULT A33 - FAN SPEED INCORRECT
OUTSIDE MODEL
FAULT A19 - FALSE FLAME AFTER DEMAND
OUTSIDE MODEL
FAULT E01 - PRIMARY PRESSURE TOO HIGH
OUTSIDE MODEL
FAULT E00 - RECHECK AFTER LOCKOUT?
OUTSIDE MODEL
FAULT E03 - FLOW TEMPERATURE ABNORMALLY HIGH
OUTSIDE MODEL
FAULT A27
INTENTIONALLY BLANK HEADER FOR FAULT CODE
IGNITES BUT BAFFLES
CONDENSATE TRAP AND DRAIN
IGNITES BUT BAFFLES
BURNER
IGNITES BUT BAFFLES
HEAT EXCHANGER FLUE WAYS
IGNITES BUT BAFFLES
HEAT EXCHANGER SUMP
IGNITES BUT BAFFLES
DUCT - AIR INLET
FAULT 1
ELECTRODE LEAD FLAME SENSE
NOT ESTABLISHING
ELECTRODE FLAME SENSE
NOT ESTABLISHING
GAS INLET PRESSURE
DHW WATER COLD RADS HEAT
DIVERTER VALVE BODY
EXHAUST
FLUE OUTLET
BURNER IGNITES LOW FAN PRESSURE
CONDENSATE TRAP AND DRAIN
FAULT 1
HEAT EXCHANGER FLUE WAYS
BURNER IGNITES LOW PRESSURE
HEAT EXCHANGER SUMP
FAULT 1
SENSOR OVERHEAT
BURNER IGNITES
DUCT - AIR INLET
SPARK PRESENT
ELECTRODE IGNITION LEAD
FAULT 1
ELECTRODE IGNITION
FAULT 1
CONDENSATE TRAP AND DRAIN
BURNER IGNITES - PRESSURE OK
HEAT EXCHANGER FLUE WAYS
BURNER IGNITES PRESSURE OK
HEAT EXCHANGER SUMP
FAULT 2
BURNER
FAULT 1
INJECTOR
FAULT CODE E03
SYSTEM CHARGE PRESSURE
FAULT CODE E03 - NO POWER TO PUMP
CONTROL PCB
FAULT CODE E03
PUMP HARNESS
FAULT CODE E03
SENSOR RETURN
FAULT CODE E03
SENSOR DHW
FAULT CODE E03
BYPASS
FAULT CODE E03
HEAT EXCHANGER GAS/WATER
FAULT CODE A27
FLUE TEMPERATURE SENSOR
CH OP UP TO TEMP RADS COLD
DIVERTER VALVE BODY
FAULT 1
PCB SWITCH POSITION
BLOWN
FUSE F1
FAULT1
SPARK GENERATOR
OPEN CIRCUIT
SPARK GENERATOR
IGNITES BUT DOESNT ESTABLISH
DUCT - AIR INLET
CALIBRATION 1
SENSOR DHW
FAULT 2
PUMP
FAULT
ELECTRICAL SAFETY CHECKS
CALIBRATION 2
SENSOR DHW
FAULT 1
PUMP HARNESS
FAULT 4
PUMP
FAULT 1
BYPASS
CALIBRATION 3
SENSOR DHW
CALIBRATION 4
SENSOR DHW
PUMP FUNCTION 3
CONTROL PCB
FAULT 2
PUMP HARNESS
FAULT
SYSTEM CHECKS
POOR SUPPLY 4
GAS INLET PRESSURE
CALIBRATION 4
SENSOR FLOW
CALIBRATION 4
SENSOR RETURN
CALIBRATION 6
SENSOR DHW
FAULT 3
CONDENSATE TRAP AND DRAIN
FAULT 2
FLUE ASSEMBLY
FAULT1
ROOM STAT/LINK
FAULT 3
DIVERTER VALVE BODY
FAULT 3
BYPASS
CALIBRATION 6
SENSOR FLOW
CH DEMAND FAULT 5
CONTROL PCB
POOR SUPPLY 5
GAS INLET PRESSURE
FAULT 2
INJECTOR
FAULT 3
FLUE ASSEMBLY
FAULT 3
FAN
CALIBRATION 5
SENSOR FLOW
CALIBRATION 5
SENSOR RETURN
FAULT 1
SECONDARY EXPANSION VESSEL
FAULT 2
BYPASS
FAULT 5
PUMP
CH DEMAND FAULT 2
CONTROL PCB
FAULT 4
CONDENSATE TRAP AND DRAIN
CALIBRATION 6
SENSOR RETURN
FAULT CODE E04 / E06
SENSOR FLOW
FAULT CODE E04 / E06
CONTROL PCB
FAULT CODE E07 / E08
CONTROL PCB
FAULT CODE E07 / E08
SENSOR DHW
TYPE OF DIAGNOSTIC PROCEDURE
Z REDIRECT
ENHANCED FAULT CODES
Z REDIRECT
FAULT CODE E22
CONTROL PCB
FAULT CODE A05 / E42
CONTROL PCB
FAULT CODE A03 - OPEN CCT
SENSOR OVERHEAT
FAULT CODE A03
SYSTEM CHARGE PRESSURE
FAULT CODE E40 / E41
SENSOR RETURN
FAULT CODE E29
KIT - TRANSMITTER CONVERTER - HUBA
FAULT CODE A33 - PERMANENT VOLTAGES ABSENT
CONTROL PCB
FAULT CODE A33 - NO DEMAND TO FAN
CONTROL PCB
FAULT CODE A33
CABLE - 5-WAY TO MVL FAN
FAULT 1
ON/OFF SWITCH
FAULT CODE A03 - NO POWER TO PUMP
CONTROL PCB
FAULT CODE A03
PUMP HARNESS
FAULT CODE A03
SENSOR FLOW
FAULT CODE A03
SENSOR RETURN
FAULT CODE A03
SENSOR DHW
FAULT CODE A03
BYPASS
FAULT CODE A03
HEAT EXCHANGER GAS/WATER
FAULT CODE A19 - PASSING
GAS VALVE
FAULT CODE A19
ELECTRODE FLAME SENSE
FAULT CODE A19
CONDENSATE TRAP AND DRAIN
FAULT CODE A19
FLUE ASSEMBLY
FAULT CODE A19 - STUCK IN FAULT
CONTROL PCB
FAULT CODE A15
SYSTEM CHARGE PRESSURE
FAULT CODE A15 - NO POWER TO PRESSURE SWITCH
CONTROL PCB
FAULT CODE A15
SYSTEM PRESSURE SENSOR
FAN RUNS
SYSTEM CHARGE PRESSURE
FAN RUNS - NO POWER TO PRESSURE SWITCH
CONTROL PCB
FAN RUNS
SYSTEM PRESSURE SENSOR
OPEN CIRCUIT
SENSOR DHW
CALIBRATION 1
SENSOR FLOW
CALIBRATION 1
SENSOR RETURN
CH OPERATION
EXPANSION VESSEL 12 LITRE (CH)
FAULT CODE E01
SYSTEM CHARGE PRESSURE TOO HIGH
FAULT CODE E01
GAUGE - PRESSURE
FAULT CODE E01
EXPANSION VESSEL 12 LITRE (CH)
FAULT CODE E01 - NO POWER TO PRESSURE SWITCH
CONTROL PCB
FAULT CODE E01
SYSTEM PRESSURE SENSOR
FAULT CODE E00
CONTROL PCB
FAULT CODE E03
SENSOR FLOW
FAULT CODE E03
CONTROL PCB
FAULT CODE A20 - PASSING
GAS VALVE
FAULT CODE A20
ELECTRODE FLAME SENSE
FAULT CODE A20
CONDENSATE TRAP AND DRAIN
FAULT CODE A20
FLUE ASSEMBLY
DHW OPERATION SEIZED
DIVERTER VALVE BODY
FAULT CODE A19
HEAT EXCHANGER FLUE WAYS
FAULT CODE A20
HEAT EXCHANGER FLUE WAYS
FAULT CODE A20 / E20
HEAT EXCHANGER SUMP
FAULT CODE A19
HEAT EXCHANGER SUMP
FAN RUNS - PERMANENT VOLTAGES ABSENT
CONTROL PCB
FAN RUNS - NO DEMAND TO FAN
CONTROL PCB
FAN RUNS
CABLE - 5-WAY TO MVL FAN
IGNITES BUT BAFFLES
GAS INLET PRESSURE
IGNITES BUT BAFFLES
FLUE OUTLET
IGNITES BUT BAFFLES
GAS VALVE
FAULT 1
DIVERTER VALVE HEAD
FAULT 2
FAN
POOR SUPPLY 1
GAS INLET PRESSURE
FAULT 1
GAS VALVE
GAS VALVE FUNCTION
CONTROL PCB
BURNER IGNITES - WITH PRESSURE DROP
GAS VALVE
FAULT CODE E03
DHW CALORIFIER CIRCULATION
FAULT CODE E03
NO FAULT FOUND OVERHEAT
FAULT CODE E03 - TRIPPING EARLY
SENSOR OVERHEAT
FAULT CODE E03 - NOT SHUTTING DOWN PROPERLY
CONTROL PCB
FAULT CODE A27
CONTROL PCB
FAULT A27
HARNESS FLUE SENSOR
FAULT 3
DIVERTER VALVE HEAD
DHW DEMAND FUNCTION 2
CONTROL PCB
FLAME SENSE FUNCTION
CONTROL PCB
POWER FUNCTION
CONTROL PCB
DISPLAY FUNCTION
CONTROL PCB
SPARK GEN FUNCTION
CONTROL PCB
SPARK GEN FUNCTION 2
CONTROL PCB
FAULT 1
DIVERTER VALVE BODY
DIVERTER DHW FUNCTION
CONTROL PCB
FAULT 2
DIVERTER VALVE BODY
DIVERTER DHW FUNCTION 2
CONTROL PCB
FAULT 1
PUMP
FAULT 1
DHW CALORIFIER CIRCULATION
FAULT 3
PUMP
FAULT 1
HEAT EXCHANGER GAS/WATER
PUMP FUNCTION 1
CONTROL PCB
CIRCULATION 1
DHW SYSTEM/CYLINDER
FAULT 4
BURNER
FAULT 2
GAS VALVE
CH DEMAND FAULT 1
CONTROL PCB
FAULT 1
SECONDARY PRESSURE RELIEF VALVE
CH DEMAND FAULT 6
CONTROL PCB
FAULT CODE E04 / E06
Z REDIRECT
FAULT CODE E07 / E08
Z REDIRECT
FAULT CODE E21
CONTROL PCB
FAULT CODE E40 / E41
CONTROL PCB
FAULT CODE A05 / E42
Z REDIRECT
FAULT CODE A03 - STUCK IN FAULT
CONTROL PCB
FAULT CODE E29
CONTROL PCB
FAULT CODE A33
FAN
FAULT CODE A03
NO FAULT FOUND OVERHEAT
FAULT CODE A03 - TRIPPING EARLY
SENSOR OVERHEAT
FAULT CODE A03
DHW CALORIFIER CIRCULATION
FAULT CODE A03 - NOT SHUTTING DOWN PROPERLY
CONTROL PCB
FAULT CODE A15 - STUCK IN FAULT
CONTROL PCB
CH OPERATION
HOSE - CONNECTING
FAULT CODE E01
HOSE - CONNECTING
FAULT CODE E01 - STUCK IN FAULT
CONTROL PCB
FAULT CODE E00
Z REDIRECT
FAULT 2
DIVERTER VALVE HEAD
FAULT CODE A19 - RETURNING TO FAULT CODE
CONTROL PCB
FAULT CODE A20 - RETURNING TO FAULT CODE
CONTROL PCB
FAN RUNS
FAN
INLET PRESSURE OK BUT NO DROP DURING IGNITION
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
INLET PRESSURE ABSENT OR DIES AWAY DURING SPARKING
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
BOILER GOES TO OVERHEAT LOCKOUT BEFORE 80°C
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER TO MAXIMUM DOES OVERHEAT OCCUR
BOILER CONTINUES FIRING PAST 85°C
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER TO MAXIMUM DOES OVERHEAT OCCUR
Water cold, radiators heat
CHARACTERISTIC TEST FROM DHW OPERATION
Boiler reaches temperature but water cold
CHARACTERISTIC TEST FROM DHW OPERATION
Radiators heat when DHW only calling
CHARACTERISTIC TEST FROM DHW OPERATION
Boiler reaches temperature but radiators cold
CHARACTERISTIC TEST FROM CH OPERATION
Boiler kettling
CHARACTERISTIC TEST FROM DHW OPERATION
Boiler temperature low and system temperature low
CHARACTERISTIC TEST FROM CH OPERATION
Boiler kettling
CHARACTERISTIC TEST FROM DHW OPERATION
Appliance fires but shuts down before water reaches temperature
CHARACTERISTIC TEST FROM DHW OPERATION
Water heats OK but discharge on cylinder blows
CHARACTERISTIC TEST FROM DHW OPERATION
BOILER GOES TO OVERHEAT LOCKOUT BEFORE 80°C
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER TO MAXIMUM DOES OVERHEAT OCCUR
BOILER CONTINUES FIRING PAST 85°C
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER TO MAXIMUM DOES OVERHEAT OCCUR
EXCESSIVE SYSTEM PERSSURE RISE OR E01 OCCURS DURING OPERATION
CHARACTERISTIC TEST FROM CH OPERATION
BURNER IGNITES SMOOTHLY BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BURNER IGNITES BUT BAFFLES OUT
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
20/02/2018 14:11:45 1802_1_50_1 06/03/2018 13:17:49
28/02/2018 13:19:22
SENSOR OVERHEAT RESISTANCE
{ISOLATEMAINSPOWER}<
OBSERVATION SPARK GENERATOR TYPE
WHICH TYPE OF SPARK GENERATOR IS FITTED?
VOLTAGE AT CONNECTOR J8
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB AS NECESSARY
TEMPERATURE DIFFERENTIAL FLOW AND RETURN CH
{ISOLATEMAINSPOWER}
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS SHOWN
RESISTANCE FLUE SENSOR AND HARNESS
{ISOLATEMAINSPOWER}
DISCONNECT PLUG J11 FROM THE PCB
RESISTANCE FLUE SENSOR
{ISOLATEMAINSPOWER}<
PANEL SWITCH POSITION
{ISOLATEMAINSPOWER}
RESISTANCE SPARK GENERATOR PACTROL
{ISOLATEMAINSPOWER}<
DIVERTER VALVE OPERATION VOLTS
{ISOLATEMAINSPOWER}<
SENSOR DHW
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR J13 FROM THE PCB
PUMP VOLTAGE
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB CONNECTIONS AS NECESSARY
DIVERTER VALVE OPERATION VOLTS
{ISOLATEMAINSPOWER}<
SENSOR DHW
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR J13 FROM THE PCB
PUMP RUNS
DHW TEMPERATURE SELECTOR TO MAXIMUM POSITION
PUMP VOLTAGE
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB CONNECTIONS AS NECESSARY
SENSOR DHW
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR J13 FROM THE PCB
DIVERTER VALVE VOLTAGE (CH)
{ISOLATEMAINSPOWER}<
FAN PRESSURE CHECK
{ISOLATEMAINSPOWER}<
SENSOR FLOW
{ISOLATEMAINSPOWER}<
SENSOR DHW
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR J13 FROM THE PCB
SENSOR RETURN
{ISOLATEMAINSPOWER}<
SYSTEM CHARGE PRESSURE
{ISOLATEMAINSPOWER}
VOLTAGE FAN AT PCB
{ISOLATEMAINSPOWER}
REMOVE THE CONNECTOR FROM THE FAN AND MAKE SAFE
NO DEMAND
OBSERVATION BOILER RESET OVERHEAT
ENSURE APPLIANCE IS COOL
SENSOR OVERHEAT RESISTANCE
{ISOLATEMAINSPOWER}<
INSPECTION JP11 LINK
{ISOLATEMAINSPOWER}
RESISTANCE ON / OFF SWITCH
{ISOLATEMAINSPOWER}<
VOLTAGE AT CONNECTOR J8
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB AS NECESSARY
TEMPERATURE DIFFERENTIAL FLOW AND RETURN CH
{ISOLATEMAINSPOWER}
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS SHOWN
SYSTEM CHARGE PRESSURE
{ISOLATEMAINSPOWER}
SYSTEM CHARGE PRESSURE (TOO HIGH)
{ISOLATEMAINSPOWER}
PRESSURE EXPANSION VESSEL (CH)
{ISOLATEMAINSPOWER}
DRAIN PRIMARY CIRCUIT OF WATER
SENSOR FLOW
{ISOLATEMAINSPOWER}<
PRESSURE TIGHTNESS TEST
{ISOLATEMAINSPOWER}
ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
BURNER
{ISOLATEMAINSPOWER}<
HEAT EXCHANGER FLUE WAYS
{ISOLATEMAINSPOWER}<
INSPECTION HEAT EXCHANGER SUMP
{ISOLATEMAINSPOWER}<
INSPECTION AIR INTAKE
{ISOLATEMAINSPOWER}
REMOVE AIR INTAKE FROM BOILER
FLAME SENSE ELECTRODE LEAD
{ISOLATEMAINSPOWER}<
FLAME SENSE ELECTRODE
{ISOLATEMAINSPOWER}
REMOVE FLAME SENSE ELECTRODE
GAS INLET PRESSURE
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
DIVERTER VALVE BODY
{ISOLATEMAINSPOWER}
REMOVE DIVERTER VALVE ACTUATOR HEAD
FAN PRESSURE
{ISOLATEMAINSPOWER}<
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
DISCONNECT CONDENSATE TRAP
BURNER
{ISOLATEMAINSPOWER}<
HEAT EXCHANGER FLUE WAYS
{ISOLATEMAINSPOWER}<
INSPECTION HEAT EXCHANGER SUMP
{ISOLATEMAINSPOWER}<
PRESSURE GAS INLET AND DROP
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
SPARKING PRESENT
{ISOLATEMAINSPOWER}<
INSPECTION AIR INTAKE
{ISOLATEMAINSPOWER}
REMOVE AIR INTAKE FROM BOILER
RESISTANCE IGNITION LEAD
{ISOLATEMAINSPOWER}<
IGNITION ELECTRODE
{ISOLATEMAINSPOWER}
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
DISCONNECT CONDENSATE TRAP
HEAT EXCHANGER FLUE WAYS
{ISOLATEMAINSPOWER}<
INSPECTION HEAT EXCHANGER SUMP
{ISOLATEMAINSPOWER}<
BURNER
{ISOLATEMAINSPOWER}<
INJECTOR
{ISOLATEMAINSPOWER}
REMOVE GAS VALVE AND INJECTOR ASSEMBLY
SYSTEM CHARGE PRESSURE
{ISOLATEMAINSPOWER}
PUMP RUNS
DHW TEMPERATURE SELECTOR TO MAXIMUM POSITION
PUMP HARNESS
{ISOLATEMAINSPOWER}
SENSOR RETURN
{ISOLATEMAINSPOWER}<
SENSOR DHW
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR J13 FROM THE PCB
BYPASS
{ISOLATEMAINSPOWER}<
TEMPERATURE DIFFERENTIAL FLOW AND RETURN DHW
{ISOLATEMAINSPOWER}<
TEMPERATURE DIFFERENTIAL FLOW AND RETURN CH
{ISOLATEMAINSPOWER}
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS SHOWN
OBSERVATION RUN BOILER TO MAXIMUM DOES OVERHEAT OCCUR
ATTACH TEMPERATURE CLAMP TO BOILER FLOW PIPE AS SHOWN
DIVERTER VALVE BODY
{ISOLATEMAINSPOWER}
REMOVE DIVERTER VALVE ACTUATOR HEAD
RESISTANCE FUSE PCB
{ISOLATEMAINSPOWER}<
RESISTANCE SPARK GENERATOR ERA
{ISOLATEMAINSPOWER}<
INSPECTION AIR INTAKE
{ISOLATEMAINSPOWER}
REMOVE AIR INTAKE FROM BOILER
DIVERTER VALVE HEAD POSITION
DHW TEMPERATURE SELECTOR TO MAXIMUM POSITION
PUMP RUNS
DHW TEMPERATURE SELECTOR TO MAXIMUM POSITION
DIVERTER VALVE HEAD POSITION
ENSURE DHW DEMAND IS SATISFIED I.E. CYLINDER UP TO TEMPERATURE
BYPASS
{ISOLATEMAINSPOWER}<
DIVERTER VALVE MANUAL POSITION
{ISOLATEMAINSPOWER}<
DIVERTER VALVE HEAD POSITION
DHW TEMPERATURE SELECTOR TO MAXIMUM POSITION
PUMP HARNESS
{ISOLATEMAINSPOWER}
PUMP HARNESS
{ISOLATEMAINSPOWER}
BYPASS
{ISOLATEMAINSPOWER}<
SENSOR DHW
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR J13 FROM THE PCB
GAS INLET PRESSURE
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
SENSOR FLOW
{ISOLATEMAINSPOWER}<
SENSOR RETURN
{ISOLATEMAINSPOWER}<
SENSOR DHW
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR J13 FROM THE PCB
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
DISCONNECT CONDENSATE TRAP
DIVERTER VALVE BODY
{ISOLATEMAINSPOWER}
REMOVE DIVERTER VALVE ACTUATOR HEAD
SENSOR FLOW
{ISOLATEMAINSPOWER}<
SENSOR RETURN
{ISOLATEMAINSPOWER}<
GAS INLET PRESSURE
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
BURNER INJECTOR
{ISOLATEMAINSPOWER}<
SENSOR FLOW
{ISOLATEMAINSPOWER}<
SENSOR RETURN
{ISOLATEMAINSPOWER}<
SECONDARY EXPANSION VESSEL CHARGE PRESSURE
{ISOLATEMAINSPOWER}<
BYPASS
{ISOLATEMAINSPOWER}<
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
DISCONNECT CONDENSATE TRAP
SYSTEM CHARGE PRESSURE
{ISOLATEMAINSPOWER}
VOLTAGE FAN DEMAND AT PCB
{ISOLATEMAINSPOWER}<
RESISTANCE HARNESS FAN
{ISOLATEMAINSPOWER}
DISCONNECT FAN HARNESS FROM THE FAN AND PCB
PUMP RUNS
DHW TEMPERATURE SELECTOR TO MAXIMUM POSITION
SENSOR FLOW
{ISOLATEMAINSPOWER}<
PUMP HARNESS
{ISOLATEMAINSPOWER}
SENSOR RETURN
{ISOLATEMAINSPOWER}<
BYPASS
{ISOLATEMAINSPOWER}<
SENSOR DHW
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR J13 FROM THE PCB
TEMPERATURE DIFFERENTIAL FLOW AND RETURN DHW
{ISOLATEMAINSPOWER}<
TEMPERATURE DIFFERENTIAL FLOW AND RETURN CH
{ISOLATEMAINSPOWER}
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS SHOWN
OBSERVATION RUN BOILER TO MAXIMUM DOES OVERHEAT OCCUR
ATTACH TEMPERATURE CLAMP TO BOILER FLOW PIPE AS SHOWN
PRESSURE TIGHTNESS TEST
{ISOLATEMAINSPOWER}
ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
FLAME SENSE ELECTRODE
{ISOLATEMAINSPOWER}
REMOVE FLAME SENSE ELECTRODE
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
DISCONNECT CONDENSATE TRAP
HEAT EXCHANGER FLUE WAYS
{ISOLATEMAINSPOWER}<
PRESSURE STANDING RETURN
{ISOLATEMAINSPOWER}
ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
SYSTEM PRESSURE SENSOR
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB CONNECTIONS AS NECESSARY
SYSTEM PRESSURE SENSOR VOLTAGE
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB CONNECTIONS AS NECESSARY
SYSTEM PRESSURE SENSOR
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB CONNECTIONS AS NECESSARY
SYSTEM PRESSURE SENSOR VOLTAGE
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB CONNECTIONS AS NECESSARY
SENSOR DHW
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR J13 FROM THE PCB
SENSOR FLOW
{ISOLATEMAINSPOWER}<
SENSOR RETURN
{ISOLATEMAINSPOWER}<
PRESSURE EXPANSION VESSEL (CH)
{ISOLATEMAINSPOWER}
DRAIN PRIMARY CIRCUIT OF WATER
OBSERVATION SYSTEM PRESSURE RISE (E01)
{ISOLATEMAINSPOWER}
SYSTEM PRESSURE SENSOR
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB CONNECTIONS AS NECESSARY
SYSTEM PRESSURE SENSOR VOLTAGE
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB CONNECTIONS AS NECESSARY
FLAME SENSE ELECTRODE
{ISOLATEMAINSPOWER}
REMOVE FLAME SENSE ELECTRODE
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
DISCONNECT CONDENSATE TRAP
HEAT EXCHANGER FLUE WAYS
{ISOLATEMAINSPOWER}<
DIVERTER VALVE BODY
{ISOLATEMAINSPOWER}
REMOVE DIVERTER VALVE ACTUATOR HEAD
INSPECTION HEAT EXCHANGER SUMP
{ISOLATEMAINSPOWER}<
INSPECTION HEAT EXCHANGER SUMP
{ISOLATEMAINSPOWER}<
VOLTAGE FAN AT PCB
{ISOLATEMAINSPOWER}
REMOVE THE CONNECTOR FROM THE FAN AND MAKE SAFE
NO DEMAND
VOLTAGE FAN DEMAND AT PCB
{ISOLATEMAINSPOWER}<
RESISTANCE HARNESS FAN
{ISOLATEMAINSPOWER}
DISCONNECT FAN HARNESS FROM THE FAN AND PCB
GAS INLET PRESSURE
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
DISCONNECT CONDENSATE TRAP
System Information
- Total Tests: 411
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control