Set Appliance State:
Mains Power Off
Boiler Thermal Store must NOT be at maximum temperature.
Models with Programmer: Rocker Switch to Continuous.
Models without Programmer: Rocker Switch to ON.
Models with Programmer: Rocker Switch to Continuous.
Models without Programmer: Rocker Switch to ON.
Gas On
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure Mains Voltage across the Yellow Wire
(connected to the Green Neon) and the Main
Appliance Neutral.
Note:
Please remove the Boiler Facia before carrying out test.
(connected to the Green Neon) and the Main
Appliance Neutral.
Note:
Please remove the Boiler Facia before carrying out test.

Isolate as per TOPs P4
and refit as necessary