Set Appliance State:
Mains Power Off
Boiler Thermal Store must not be at maximum temperature.
Models with Programmer: Rocker Switch to Continuous.
Models without Programmer: Rocker switch to On.
Models with Programmer: Rocker Switch to Continuous.
Models without Programmer: Rocker switch to On.
Gas On
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure Mains Voltage across Connection 7 (Yellow) of the Full Sequence Ignition Box and the Main Appliance Neutral Connection.

Isolate as per TOPs P4
and refit as necessary