Set Appliance State:
Mains Power Off
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC voltage across pins 1 and 4 on connector X2 at the PCB.
This voltage will vary according the boiler system pressure.
Approx voltage should be 1.7 to 1.9 volts DC.
Note:
Colour of wires may change but test points remain the same.
This voltage will vary according the boiler system pressure.
Approx voltage should be 1.7 to 1.9 volts DC.
| System pressure | Voltage DC | 0 bar | 1.2 |
| 1 bar | 1.7 |
| 2 bar | 2.2 |
| 3 bar | 2.8 |
Note:
Colour of wires may change but test points remain the same.

Isolate as per TOPs P4
and refit as necessary