Set Appliance State:
Mains Power Off
CH Demand
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Access the diagnostic display by pressing the Mode and + buttons until the screen changes. Use the +/- buttons to scroll to 96, then hold the mode button for 5 secs.
The screen will alternately display L1 and a number (usually 0).
This indicates that you have level 1 access, the number being the diagnostic number.
Use +/- to scroll to the desired number then press the mode button display the value.
(You can use this link to see all of the diagnostic code numbers if required)
In this instance d2, this will display the anticycle time in minutes
It should be between 3 - 60 mins.
The screen will alternately display L1 and a number (usually 0).
This indicates that you have level 1 access, the number being the diagnostic number.
Use +/- to scroll to the desired number then press the mode button display the value.
(You can use this link to see all of the diagnostic code numbers if required)
In this instance d2, this will display the anticycle time in minutes
It should be between 3 - 60 mins.