Set Appliance State:
Ensure no demands
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between the bottom pin (as indicated by red probe in the picture)
at connector X2 to pin 5 (white) at connector X5 on the display PCB.
With no demand voltage should be approximately 0V DC.
at connector X2 to pin 5 (white) at connector X5 on the display PCB.
With no demand voltage should be approximately 0V DC.

Isolate as per TOPs P4
and refit as necessary