Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to display PCB
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between pin 3 (brown)
and pin 4 (dark blue) at X5 on the display PCB.
Voltage should be approximately 24V AC.
and pin 4 (dark blue) at X5 on the display PCB.
Voltage should be approximately 24V AC.

Isolate as per TOPs P4
and refit as necessary