Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Attach U gauge to inlet pressure test point
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow self-check to complete.
Turn CH demand ON.
Allow fan to run and ignition sequence to commence.
Observe the U-gauge. The inlet pressure should remain at or above 20mbar (37mb for LPG) throughout boiler ignition sequence.
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.
Turn CH demand ON.
Allow fan to run and ignition sequence to commence.
Observe the U-gauge. The inlet pressure should remain at or above 20mbar (37mb for LPG) throughout boiler ignition sequence.
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.
Isolate as per TOPs P4