Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove plug from the pump
Measurement:
Test 1:
Measure the resistance between the top and middle connections at the pump.
Resistance should be approximately 225Ω.
If different pump has been fitted resistance may be
different, ErP pumps will be significantly higher
Test 2:
Measure the resistance between the top and bottom connections at the pump.
Resistance should be greater than 1MΩ (or O.L.)
Measure the resistance between the top and middle connections at the pump.
Resistance should be approximately 225Ω.
If different pump has been fitted resistance may be
different, ErP pumps will be significantly higher
Test 2:
Measure the resistance between the top and bottom connections at the pump.
Resistance should be greater than 1MΩ (or O.L.)

Isolate as per TOPs P4
and refit as necessary