Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
CH Demand
Attach a pressure gauge to the burner pressure test point
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Measure the burner pressure as boiler reaches
the sparking stage of the ignition sequence.
There should be a positive burner pressure that slowly
increases as the gas valve "soft light" function operates.
Does the burner pressure operate as above?
Notes:
1. Burner pressure may not reach operating pressure before boiler goes to lockout. Reset as necessary until test is complete.
2. When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.