Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the plug of the DHW temperature sensor from the PCB it is adjacent to the low voltage DC terminal strip marked ST 18 on the PCB
Measurement:
Measure the resistance across the blue and brown connections on the disconnected plug.
Resistance will vary according to the temperature of the water.
The lower the temperature the higher the resistance.
The resistance should conform to the table below:
Note:
Expected temperature should not exceed 60 degrees C.
Resistance will vary according to the temperature of the water.
The lower the temperature the higher the resistance.
The resistance should conform to the table below:
| Temperature °C | Resistance in kOhms |
| 20-30 | 14.0-11.8 |
| 40-50 | 9.0-7.5 |
| 60-70 | 5.7-4.5 |
Note:
Expected temperature should not exceed 60 degrees C.

Isolate as per TOPs P4