XSol Diagnostic System

Interactive Test Sequence Navigator

Welcome to the XSol Diagnostic System

This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.

Start Diagnostic Sequence

or choose a specific test below:

BG 330 AND HXI RANGE

GLOBALLY REPLACED

Next: &737, *

BG 330

Next: &1602, !f2

OPERATIONAL SEQUENCE

Next: &271, !f192

DISPLAY

Next: &21, ?441, ?509

FAN RUNS

SET TEMPERATURE SELECTOR TO MAX

Next: &857, ?513, ?558

BURNER ESTABLISHES

SET TEMPERATURE SELECTOR TO MAX

Next: &93, f980

DHW OPERATION

SET TEMPERATURE SELECTOR TO MAX

Next: &761, ?94, ?96, ?98, ?100

CH OPERATION

SET TEMPERATURE SELECTOR TO MAX
ENSURE ALL HEATING CONTROLS ARE CALLING

Next: &999, ?141, ?143, ?145

DIRECTIONAL CHOICE

Next: &3, !f270

F19 FAULT CODE

Next: &nff, f329

F16 FAULT CODE

Next: &nff, f339

F6 FAULT CODE

OUT OF MODEL

Next: &nff, f343

F10 FAULT CODE

Next: &nff, f349

F8 / F12 FAULT CODE

HEADER FOR F8 / F12 FAULT CODE - OUTSIDE MODEL

Next: &nff, f355

OVERHEAT INVESTIGATION

OUT OF MODEL

Next: &nff, f361

F2 F3 FAULT CODE

OUT OF MODEL

Next: &nff, f1009

F11 / F13 FAULT CODE

HEADER FOR F11 / F13 FAULT CODE - OUTSIDE MODEL

Next: &nff, f1530

TEMP FAULT CODE

Next: &nff, f405

INFORMATION DIP SWITCHES

THERE ARE A BANK OF

Next: &nff, !f437

CASE OFF

Next: &1, !f738

UNIVERSAL DISPLAY SET UP

Next: &nff, !f746

MAXIMUM FAN SPEED SET UP

Next: &nff, !f748

COMBUSTION ANALYSIS MAX AND MIN

RELEASE THE FRONT FACIA BY GENTLY PRISING UP THE RETAINING
LATCHES AT THE TOP OF THE FACIA

Next: &140, f1702

F17 FAULT CODE

OUT OF MODEL

Next: &nff, f774

FUSE INVESTIGATION IRIS

OUTSIDE MODEL

Next: &nff, f782

FUSE INVESTIGATION SYMS

OUTSIDE MODEL

Next: &nff, f802

F14 FLOW ABOVE 95 DEG

OUT OF MODEL

Next: &nff, f1162

BURNER IGNITION

SET TEMPERATURE SELECTOR TO MAX

Next: &85, ?858, ?860, ?862

BOILER SHUT DOWN

SET TEMPERATURE SELECTOR TO MAX
ENSURE ALL HEATING CONTROLS ARE CALLING

Next: &nff, f1000

F18 FAULT CODE

Next: &nff, !f1601

F2 F3

HARNESS - CONTROL

Next: End

FAN SPEED CONTROL

FAN ASSEMBLY

Next: End

F3 NO VOLTAGE ON DEMAND

PCB - XI RANGE INCL BG330

Next: End

HALL SENSOR

FAN ASSEMBLY

Next: End

BLOWING FUSE

GAS VALVE ASSEMBLY

Next: End

BLOWN FUSE

IGNITOR UNIT

Next: End

FUSE F1 IRIS

GAS VALVE ASSEMBLY

Next: End

FUSE F1 IRIS

IGNITOR UNIT

Next: End

FUSE F1 IRIS

SUPPLY - DC FAN

Next: End

DISPLAY PCB VOLTAGE

PCB - XI RANGE INCL BG330

Next: End

NO DISPLAY

HARNESS - INTERFACE

Next: End

BLOWING FUSES

SYSTEM PUMP FAULT

Next: End

IRISBLOWING FUSES

SYSTEM PUMP FAULT

Next: End

F14 FAULT

PCB - XI RANGE INCL BG330

Next: End

FAULT 4F14

SYSTEM PUMP FAULT

Next: End

BLOWN

FUSE F1

Next: End

FATIGUE SYSMI

FUSE (FUSED SPUR)

Next: End

FATIGUE IRIS

FUSE (FUSED SPUR)

Next: End

BLOWN

FUSE F1

Next: End

FAULTY 1

MOD CARD

Next: End

FAN RUNS9999

HARNESS - CONTROL

Next: End

CALIBRATION 19999

THERMISTOR - HEATING FLOW / RETURN

Next: End

CALIBRATION 19999

THERMISTOR - HEATING FLOW / RETURN

Next: End

OC 19999

THERMOSTAT - OVERHEAT

Next: End

NO FAN UNIVERSAL DISPLAY

INTERFACE CARD

Next: End

FAULT 39999

INTERFACE CARD

Next: End

FAN RUNS

HARNESS - CONTROL

Next: End

CALIBRATION 1

THERMISTOR - HEATING FLOW / RETURN

Next: End

CALIBRATION 1

THERMISTOR - HEATING FLOW / RETURN

Next: End

OC 1

THERMOSTAT - OVERHEAT

Next: End

NO FAN UNIVERSAL DISPLAY NO CARD

INTERFACE CARD

Next: End

NO FAN NO CARD

INTERFACE CARD

Next: End

PREHEAT FAN FUNCTION

PCB - XI RANGE INCL BG330

Next: End

BLOWN

FUSE F2

Next: End

BLOCKED 2

SYPHON

Next: End

FLAME SENSE

LEAD - IGNITION

Next: End

ELECTRODE RECTIFICATION

ELECTRODE - SPARK

Next: End

PUMP FUNCTION 1

PCB - XI RANGE INCL BG330

Next: End

FAULT 3

SYSTEM PUMP FAULT

Next: End

FAULT 1

Next: End

ALWAYS ON

Next: End

NO DISPLAY

PCB - XI RANGE INCL BG330

Next: End

FAULT CODE F11/12

PCB - XI RANGE INCL BG330

Next: End

OVERHEAT

Next: End

OVERHEAT 2

THERMISTOR - HEATING FLOW / RETURN

Next: End

OVERHEAT

THERMISTOR - HEATING FLOW / RETURN

Next: End

FLASHING DISPLAY (SYMS)

PCB - XI RANGE INCL BG330

Next: End

FLASHING DISPLAY IRIS PCB

HARNESS - INTERFACE

Next: End

DISPLAY FLASHING

INTERFACE CARD

Next: End

F13

WIRING HARNESSES

Next: End

FAULT CODE 11 F13

HARNESS - INTERFACE

Next: End

FAULT CODE F11/12 F13

PCB - XI RANGE INCL BG330

Next: End

FAULT 2

HARNESS - INTERFACE

Next: End

FAULT 2

INTERFACE CARD

Next: End

F12 IRIS SYMS PCB

PCB - XI RANGE INCL BG330

Next: End

DEMAND FAULT 4F11 F12

INTERFACE CARD

Next: End

F12 IRIS SYMS PCB F13

PCB - XI RANGE INCL BG330

Next: End

DEMAND FAULT 4F11 F12 F13

INTERFACE CARD

Next: End

F18

INTERFACE CARD

Next: End

INSPECTION FLUE COLLECTOR AND SEALS

FLUE COLLECTOR / SEALS

Next: End

CALIBRATION 2

THERMISTOR - HEATING FLOW / RETURN

Next: End

CALIBRATION 2

THERMISTOR - HEATING FLOW / RETURN

Next: End

DHW CALIBRATION NEW DISPLAY BOARD

INTERFACE CARD

Next: End

DHW CALIBRATION

INTERFACE CARD

Next: End

CALIBRATION 4

THERMISTOR - HEATING FLOW / RETURN

Next: End

CALIBRATION 4

THERMISTOR - HEATING FLOW / RETURN

Next: End

PUMP FUNCTION 2

PCB - XI RANGE INCL BG330

Next: End

OC 2

THERMOSTAT - OVERHEAT

Next: End

FAULT 3

FLUE

Next: End

FAULT 3

SYPHON

Next: End

DHW BOILER SHUTS DOWN PREMATURELY

INTERFACE CARD

Next: End

CALIBRATION 3

THERMISTOR - HEATING FLOW / RETURN

Next: End

CALIBRATION 3

THERMISTOR - HEATING FLOW / RETURN

Next: End

FAULT 4

SYSTEM PUMP FAULT

Next: End

CH INSUFF HEAT NEW DISPLAY BOARD

INTERFACE CARD

Next: End

CH INSUFF HEAT

INTERFACE CARD

Next: End

CALIBRATION 5

THERMISTOR - HEATING FLOW / RETURN

Next: End

CALIBRATION 5

THERMISTOR - HEATING FLOW / RETURN

Next: End

OC 3

THERMOSTAT - OVERHEAT

Next: End

FAULT 4

FLUE

Next: End

FAULT 4

SYPHON

Next: End

CH BOILER SHUTS DOWN PREMATURELY

INTERFACE CARD

Next: End

BYPASS EXTERNAL

Next: End

TEMP FAULT CODE NOT SHUTTING OFF

INTERFACE CARD

Next: End

OVERHEATLIMIT TEMP

Next: End

CH OPERATION 2F14

THERMISTOR - HEATING FLOW / RETURN

Next: End

CH CALIBRATIONF14

THERMISTOR - HEATING FLOW / RETURN

Next: End

F14TEMP FAULT CODE NOT SHUTTING OFF

INTERFACE CARD

Next: End

COMBUSTION

SYPHON

Next: End

BLOCKED999RATIO

FLUE

Next: End

COMBUSTION

BURNER

Next: End

FLUEWAYS

HEAT EXCHANGER

Next: End

FLUEWAYS SHUTTING OFF

HEAT EXCHANGER

Next: End

FAULTY

FLUE

Next: End

NOT ESTABLISHING

GAS VALVE SETTINGS

Next: End

RECTIFICATION

IGNITOR UNIT

Next: End

BLOCKED999

SYPHON

Next: End

BLOCKED999

FLUE

Next: End

NO VOLTAGE TO GAS VALVE

PCB + GAS VALVE

Next: End

GAP

ELECTRODE - SPARK

Next: End

PART BLOCKED OR DAMAGED

BURNER

Next: End

OPERATION SEQUENCE

SYSTEM CHECKS

Next: End

ELECTRICAL SAFETY CHECKS

ELECTRICAL SAFETY CHECKS

Next: End

DIRECTIONAL

SYSTEM CHECKS

Next: End

FAULT CODES

SYSTEM CHECKS

Next: End

F19FAULT F6

THERMISTOR - HEATING FLOW / RETURN

Next: End

F10F19

THERMISTOR - HEATING FLOW / RETURN

Next: End

FAULT F16

GAS VALVE ASSEMBLY

Next: End

FAULT F6

THERMISTOR - HEATING FLOW / RETURN

Next: End

F10

THERMISTOR - HEATING FLOW / RETURN

Next: End

FAULT CODE 11

HARNESS - INTERFACE

Next: End

F5 FAULTF5 FAULT

THERMOSTAT - OVERHEAT

Next: End

F5 FAULT

PCB - XI RANGE INCL BG330

Next: End

F5 FAULT CODE

SYSTEM PUMP FAULT

Next: End

F5 FAULTF25

PCB - XI RANGE INCL BG330

Next: End

F5 FAULT CODELIMIT TEMP

SYSTEM PUMP FAULT

Next: End

OVERHEATLIMIT TEMP

THERMISTOR - HEATING FLOW / RETURN

Next: End

1F5/F9LIMIT TEMP

THERMISTOR - HEATING FLOW / RETURN

Next: End

INFO

SYSTEM CHECKS

Next: End

OC 4

THERMOSTAT - OVERHEAT

Next: End

CASE OFF

SYSTEM CHECKS

Next: End

FAULTY 2

Next: End

F17

Next: End

F17 IRIS

Next: End

FUSE F1 IRIS

INTERFACE - 230V CONTROLS

Next: End

FUSE

INTERFACE - 230V CONTROLS

Next: End

DAMAGE

ELECTRODE - SPARK

Next: End

SPARK GENERATOR FUNCTION

PCB - XI RANGE INCL BG330

Next: End

F1 LOCKOUT

WIRING HARNESSES

Next: End

OVERHEAT

THERMISTOR - HEATING FLOW / RETURN

Next: End

1F5/F9

THERMISTOR - HEATING FLOW / RETURN

Next: End

1F5 FAULT

THERMOSTAT - OVERHEAT

Next: End

OVERHEAT NOT SHUTTING OFF

INTERFACE CARD

Next: End

PUMP OVERRUN

PCB - XI RANGE INCL BG330

Next: End

POOR NOT ESTABLISH

GAS SUPPLY

Next: End

CYCLING NO DEMAND

PCB - XI RANGE INCL BG330

Next: End

FAN SPEED CONTROL

PCB - XI RANGE INCL BG330

Next: End

F2 F3 FAULT

PCB - XI RANGE INCL BG330

Next: End

SYMS FUSE

HARNESS CONTROL

Next: End

NO FAULT

FUSE INVESTIGATION SYMS PCB

Next: End

SPARK GENERATOR

HARNESS IGNITION

Next: End

IRIS FUSE

HARNESS CONTROL

Next: End

SPARK GEN IRIS

HARNESS IGNITION

Next: End

NO FAULT

FUSE INVESTIGATION IRIS PCB

Next: End

FAULTY

SWITCH - RESET

Next: End

FUSE INVESTIGATION 1AFUSE IRIS

Z BLANK

Next: End

FAULTY9999

SWITCH - RESET

Next: End

SYMS PCB

Next: End

FUSE FURTHER INVESTIGATION

Z BLANK

Next: End

FUSE INVESTIGATION 1A

Z BLANK

Next: End

FAULTY

INTERFACE CARD

Next: End

PUMP

HARNESS - PUMP

Next: End

IRISPUMP

HARNESS - PUMP

Next: End

F14 FAULT

SYSTEM PUMP FAULT

Next: End

FAN CONTROL 29999

PCB - XI RANGE INCL BG330

Next: End

FAN CONTROL 2

PCB - XI RANGE INCL BG330

Next: End

FAN RUN PREHEAT

SUPPLY - DC FAN

Next: End

PREHEAT FAN RUN

PCB - XI RANGE INCL BG330

Next: End

PREHEAT DEMAND

FAN ASSEMBLY

Next: End

FAN RUN PREHEAT 2

SUPPLY - DC FAN

Next: End

FAULT 1

SYSTEM PUMP FAULT

Next: End

FAULT 1

Next: End

PERMANENT DEMAND 240

INTERFACE - 230V CONTROLS

Next: End

NO FAN OPERATION

FAN ASSEMBLY

Next: End

NO FAN OPERATION 2

FAN ASSEMBLY

Next: End

NO FAN OPERATION 3

FAN ASSEMBLY

Next: End

NO FAN OPERATION 4

FAN ASSEMBLY

Next: End

NO DISPLAY B2

FAN ASSEMBLY

Next: End

OVERHEAT

Next: End

FAN SPEED

PCB - XI RANGE INCL BG330

Next: End

FAULT CODE F3

FAN ASSEMBLY

Next: End

FAULT CODE F3 2

FAN ASSEMBLY

Next: End

FAULT F5F5 FAULT

PCB - XI RANGE INCL BG330

Next: End

OVERHEAT 3

HARNESS CONTROL

Next: End

OVERHEAT 4

HARNESS CONTROL

Next: End

F13 RESET

SYSTEM CHECKS

Next: End

NO DISPLAY IRIS PCB

PCB - XI RANGE INCL BG330

Next: End

NO DEMAND TO FAN

PCB - XI RANGE INCL BG330

Next: End

NO DEMAND TO FAN 2

PCB - XI RANGE INCL BG330

Next: End

NO DEMAND TO FAN 3

PCB - XI RANGE INCL BG330

Next: End

NO DEMAND TO FAN 4

PCB - XI RANGE INCL BG330

Next: End

F8 / F12 SYMS

MAIN PCB - CONNECTION FAULT

Next: End

F8 / F12 IRIS

MAIN PCB - CONNECTION FAULT

Next: End

F11 / F13 SYMS

MAIN PCB - CONNECTION FAULT

Next: End

F11 / F13 IRIS

MAIN PCB - CONNECTION FAULT

Next: End

JUMBLED DISPLAY - SYMS

MAIN PCB - CONNECTION FAULT

Next: End

JUMBLED DISPLAY - IRIS

MAIN PCB - CONNECTION FAULT

Next: End

FAULT 2

SYSTEM PUMP FAULT

Next: End

DHW CALIBRATION NEW DISPLAY BOARD

PCB - XI RANGE INCL BG330

Next: End

DHW CALIBRATION

PCB - XI RANGE INCL BG330

Next: End

DHW BOILER SHUTS DOWN PREMATURELY NEW DISPLAY BOARD

PCB - XI RANGE INCL BG330

Next: End

DHW BOILER SHUTS DOWN PREMATURELY

PCB - XI RANGE INCL BG330

Next: End

CH INSUFF HEAT NEW DISPLAY BOARD

PCB - XI RANGE INCL BG330

Next: End

CH INSUFF HEAT

PCB - XI RANGE INCL BG330

Next: End

FAULT 2

Next: End

CH BOILER SHUTS DOWN PREMATURELY NEW DISPLAY BOARD

PCB - XI RANGE INCL BG330

Next: End

CH BOILER SHUTS DOWN PREMATURELY

PCB - XI RANGE INCL BG330

Next: End

AIRRESCRICTIONS

BOILER NOW WORKING

Next: End

OVERHEAT2OVERHEATLIMIT TEMP

HEAT EXCHANGER

Next: End

TEMP FAULT CODE NOT SHUTTING OFF NEW DISPLAY BOARD

PCB - XI RANGE INCL BG330

Next: End

TEMP FAULT CODE NOT SHUTTING OFF

PCB - XI RANGE INCL BG330

Next: End

OVERHEATLIMIT TEMP

Next: End

F14AIRRESCRICTIONS

BOILER NOW WORKING

Next: End

F14OVERHEAT2OVERHEATLIMIT TEMP

HEAT EXCHANGER

Next: End

F14TEMP FAULT CODE NOT SHUTTING OFF NEW DISPLAY BOARD

PCB - XI RANGE INCL BG330

Next: End

F14TEMP FAULT CODE NOT SHUTTING OFF

PCB - XI RANGE INCL BG330

Next: End

COMBUSTION

GAS VALVE SETTINGS

Next: End

FLAME SENSE FUNCTION

PCB - XI RANGE INCL BG330

Next: End

POOR 3

GAS SUPPLY

Next: End

NOT PASSING 999

GAS VALVE ASSEMBLY

Next: End

GASVALVE FUNCTION

PCB - XI RANGE INCL BG330

Next: End

NOT PASSING

GAS VALVE ASSEMBLY

Next: End

DHW DEMAND FAULT 1

Next: End

F19F6 FAULT CODE

HARNESS CONTROL

Next: End

FAULT F6F10 FAULTF19

PCB - XI RANGE INCL BG330

Next: End

F6 FAULT CODEF10 FAULTF19

HARNESS CONTROL

Next: End

FAULT F16

PCB - XI RANGE INCL BG330

Next: End

FAULT F6

PCB - XI RANGE INCL BG330

Next: End

F6 FAULT CODE

HARNESS CONTROL

Next: End

FAULT F6F10 FAULT

PCB - XI RANGE INCL BG330

Next: End

F6 FAULT CODEF10 FAULT

HARNESS CONTROL

Next: End

F5 FAULT

SYSTEM PUMP FAULT

Next: End

F5 FAULTF25

SYSTEM PUMP FAULT

Next: End

OVERHEATLIMIT TEMP

HARNESS CONTROL

Next: End

OVERHEAT2LIMIT TEMP

HARNESS CONTROL

Next: End

FAN FUNCTION 1

PCB - XI RANGE INCL BG330

Next: End

NO VOLTAGE TO CONTROL PCB

PCB - XI RANGE INCL BG330

Next: End

NO CH DEMAND

INTERFACE - 230V CONTROLS

Next: End

F17

PCB - XI RANGE INCL BG330

Next: End

F17 IRIS

PCB - XI RANGE INCL BG330

Next: End

FAULT

IGNITOR UNIT

Next: End

DAMAGE

LEAD - IGNITION

Next: End

F1 LOCKOUT

PCB - XI RANGE INCL BG330

Next: End

OVERHEAT

HARNESS CONTROL

Next: End

OVERHEAT2

HARNESS CONTROL

Next: End

OVERHEAT

TEMPERATURE OVERHEAT

Next: End

OVERHEAT2OVERHEAT

HEAT EXCHANGER

Next: End

1FAULT F5

PCB - XI RANGE INCL BG330

Next: End

OVERHEAT NOT SHUTTING OFF NEW DISPLAY BOARD

PCB - XI RANGE INCL BG330

Next: End

OVERHEAT NOT SHUTTING OFF

PCB - XI RANGE INCL BG330

Next: End

Boiler shuts down prematurely

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p1615

FAN DOES NOT RUN

CHARACTERISTIC TEST FROM OBSERVATION DOES FAN RUN BEFORE FAULT

Next: p1015

FAN RUNS ON HIGH SPEED WITH NO DEMAND

CHARACTERISTIC TEST FROM OBSERVATION DOES FAN RUN BEFORE FAULT

Next: p1017

SYMS17 0 AS STANDARD NO CONTROLLER OR CARD

CHARACTERISTIC TEST FROM TYPE OF FAN CONTROL

Next: p1200

SYMS17 0 AS MOD WITH CARD

CHARACTERISTIC TEST FROM TYPE OF FAN CONTROL

Next: p1202

Boiler temperature low, system temperature low

CHARACTERISTIC TEST FROM CH OPERATION

Next: p1632

Boiler to temperature, radiators cool

CHARACTERISTIC TEST FROM CH OPERATION

Next: p144

VOLTAGE BEHAVES AS DESCRIBED

CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL (FAULT CODE F3)

Next: !p1435

VOLTAGE ABSENT (LESS THAN 1 VDC, E G 0 VDC)

CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL

Next: !p1438

VOLTAGE BEHAVES AS DESCRIBED

CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL (FAULT CODE F3)

Next: !p1441

VOLTAGE ABSENT (LESS THAN 1 VDC, E G 0 VDC)

CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL

Next: !p1443

Boiler shuts down prematurely

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p1643

VOLTAGE BEHAVES AS DESCRIBED

CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL (FAULT CODE F3)

Next: !p1496

VOLTAGE ABSENT ( LESS THAN 1 VDC, E G 0 VDC)

CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL (FAULT CODE F3)

Next: !p1498

BOILER TEMP RISES RAPIDLY

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: p1663

BOILER TEMP GOES ABOVE 87 DEGREES AND DOESNT CUT OFF

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: p1665

DIFFERENTIAL NOT OK

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: !p1667

BOILER TEMP RISES RAPIDLY

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: p1684

BOILER TEMP GOES ABOVE 87 DEGREES AND DOESNT CUT OFF

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: p1686

DIFFERENTIAL NOT OK

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: !p1688

INLET PRESSURE DOES NOT DIP TO INDICATE GAS VALVE IS OPENING

CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DIP

Next: p1776

INLET PRESSURE UNSATISFACTORY

CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DIP

Next: !p1778

DISPLAY NOT ILLUMINATED

CHARACTERISTIC TEST FROM DISPLAY

Next: p1087

DISPLAY ILLUMINATES BUT FLASHES OR DOES NOT SHOW CORRECT INFORMATION

CHARACTERISTIC TEST FROM DISPLAY

Next: p1514

Fan runs for approximately 4 seconds then stops

CHARACTERISTIC TEST FROM FAN RUNS

Next: p514

Fan does not run

CHARACTERISTIC TEST FROM FAN RUNS

Next: p559

20V OR GREATER MEASURED ON BOTH TESTS

CHARACTERISTIC TEST FROM VOLTAGE CONTROLS PCB DEMAND

Next: p563

LESS THAN 2V MEASURED ON BOTH TESTS

CHARACTERISTIC TEST FROM VOLTAGE CONTROLS PCB DEMAND

Next: !p565

SPARKING PRESENT BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM BURNER IGNITION

Next: p1769

Sparking absent

CHARACTERISTIC TEST FROM BURNER IGNITION

Next: p861

BOILER GOES TO F1 FAULT CODE WITHOUT 3 ATTEMPTS TO IGNITE

CHARACTERISTIC TEST FROM BURNER IGNITION

Next: p863

Appliance does not react to DHW demand

CHARACTERISTIC TEST FROM DHW OPERATION

Next: !p194

Boiler to temperature, DHW cool

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p97

BOILER TEMP RISES RAPIDLY

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: !p1492

BOILER TEMP GOES ABOVE 87 DEGREES AND DOESNT CUT OFF

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: p964

BOILER LOCKS OUT ON OVERHEAT BEFORE REACHING 87 DEGREES

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: p966

DIFFERENTIAL NOT OK

CHARACTERISTIC TEST FROM CH TEST TEMPERATURE

Next: !p968

Boiler temperature low, DHW temperature low

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p1604

VOLTAGE CONTROL PCB NO DEMAND

GAIN ACCESS TO PCB
USE INSULATION MAT AS REQUIRED

Next: !p1001, f1430

FAN LOOM CONTINUITY

REMOVE THE FAN LOOM FROM THE PCB (J4) AND THE FAN

Next: p1010, !f1011

RESISTANCE GAS VALVE

DISCONNECT LEADS FROM THE GAS VALVE

Next: !p1038, !f1039

RESISTANCE SPARK GENERATOR

REMOVE ELECTRICAL CONNECTORS FROM SPARK GENERATOR

Next: !p1042, !f1043

RESISTANCE GAS VALVE

DISCONNECT LEADS FROM THE GAS VALVE

Next: !p1047, !f1048

RESISTANCE SPARK GENERATOR

REMOVE ELECTRICAL CONNECTORS FROM SPARK GENERATOR

Next: !p1051, !f1052

VOLTAGE TO MAIN PCB SYMS

Next: p1090, f1091

MAINS RESET SWITCH VOLTAGE

GAIN ACCESS TO PCB (

Next: !p1092, f1093

RESISTANCE MAINS FUSE (3AMP)

REMOVE FUSE FROM FUSED SPUR

Next: !p1094, f1095

FUSE FURTHER INVESTIGATION 1A SYMS

Next: !p1100, !f1192

MAINS RESET SWITCH VOLTAGE

GAIN ACCESS TO PCB (

Next: !p1114, f1115

RESISTANCE MAINS FUSE (3AMP)

REMOVE FUSE FROM FUSED SPUR

Next: !p1116, f1117

RESISTANCE PUMP

THE PUMP IS NOT AN I

Next: !p1156, !f1157

RESISTANCE PUMP

THE PUMP IS NOT AN I

Next: !p1160, !f1161

DOES PUMP RUN

Next: p1166, f1163

PUMP VOLTAGE (CH)

SET TEMPERATURE SELE

Next: !p1164, !f1165

FAN LOOM CONTINUITY

REMOVE THE FAN LOOM FROM THE PCB (J4) AND THE FAN

Next: !p1207, !f1208

RESISTANCE DISPLAY PCB UNIVERSAL

THERMOSTAT TO MAX PO

Next: !p1560, !f1220

FAN LOOM CONTINUITY

REMOVE THE FAN LOOM FROM THE PCB (J4) AND THE FAN

Next: !p1225, !f1226

RESISTANCE DISPLAY PCB UNIVERSAL

THERMOSTAT TO MAX PO

Next: !p1558, !f1238

FAN DC SU (INPUT VOLTAGE)

REMOVE REAR COVER OF CONTROL PANEL TO EXPOSE MAIN PCB

Next: !p1243, !f1244

FAN VOLTAGE J4 DISCONNECTED

{MAINSRSSWOFF}
DISCONNECT J4 CONNECTOR AT PCB AND MAKE SAFE

Next: !p1247, f1248

FUSE RESISTANCE (DCSU)

REMOVE FUSE F2 FROM ITS HOLDER IN THE FAN DC SUPPLY CONTROL UNIT

Next: !p1249, !f1250

PUMP VOLTAGE (DHW)

ENSURE THERE IS A DE

Next: !p132, !f133

EXTERNAL CONTROLS VOLTAGE (OUTPUT) NO DEMAND

{MAINSRSSWOFF}
RE

Next: !p1431, !f1432

INSPECTION PCB CAPACITORS

{MAINSRSSWOFF}

Next: !p1445, !f1446

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: !p1504, !f1505

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: !p1506, !f1507

MAIN PCB TO DISPLAY PCB VOLTS

{MAINSRSSWOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: !p1587, !f1518

INSPECTION PCB AND CONNECTIONS

Next: p1534, !f1532

RESISTANCE HARNESS USER INTERFACE

REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB

Next: p1541, !f1542

MAIN PCB TO DISPLAY PCB VOLTS

{MAINSRSSWOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: !p1576, !f1577

MAIN PCB TO DISPLAY PCB VOLTS

{MAINSRSSWOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: !p1583, !f1584

PUMP VOLTAGE (CH)

SET TEMPERATURE SELE

Next: !p161, !f162

RESISTANCE DISPLAY PCB UNIVERSAL

THERMOSTAT TO MAX PO

Next: !p1611, !f1612

RESISTANCE DISPLAY PCB UNIVERSAL

THERMOSTAT TO MAX PO

Next: !p1628, !f1629

RESISTANCE DISPLAY PCB UNIVERSAL

THERMOSTAT TO MAX PO

Next: !p1639, !f1640

RESISTANCE DISPLAY PCB UNIVERSAL

THERMOSTAT TO MAX PO

Next: !p1656, !f1657

RESISTANCE DISPLAY PCB UNIVERSAL

THERMOSTAT TO MAX PO

Next: !p1670, !f1671

RESISTANCE DISPLAY PCB UNIVERSAL

THERMOSTAT TO MAX PO

Next: !p1691, !f1692

CONDENSATE SIPHON

Next: p1703, !f1704

RESISTANCE GAS VALVE

DISCONNECT LEADS FROM THE GAS VALVE

Next: !p1781, !f1782

RESISTANCE THERMISTOR FLOW AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: p330, f331

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: !p332, !f333

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: !p336, !f337

INSPECTION BURNER GAS SHUTDOWN

HW DEMAND

Next: !p340, !f341

RESISTANCE THERMISTOR FLOW AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: !p344, f345

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: !p346, !f347

RESISTANCE THERMISTOR RETURN AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: !p350, f351

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: !p352, !f353

RESISTANCE HARNESS USER INTERFACE

REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB

Next: p1447, !f357

BOILER RESET

ALLOW BOILER TO COOL
RESET OVERHEAT BY PUSHING IN RED BUTTON (IF NECESSARY)

Next: p362, f363

OVERHEAT THERMOSTAT

DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT

Next: p1499, !f365

PUMP VOLTAGE (CH)

SET TEMPERATURE SELE

Next: !p368, !f369

DOES PUMP RUN

Next: p406, f407

PUMP VOLTAGE (CH)

SET TEMPERATURE SELE

Next: !p408, !f409

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: !p414, !f415

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: !p418, !f419

IDENTIFY PCB

REMOVE CONTROL BOX COVER

Next: p775, f776

VOLTAGE TO MAIN PCB SYMS

Next: !p777, !f778

RESISTANCE CONTROLS INTERFACE IRIS

REMOVE REAR CONTROL

Next: p783, !f784

RESISTANCE CONTROLS INTERFACE

REMOVE REAR CONTROL

Next: p803, !f804

SPARK GENERATOR (INPUT)

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
MAINS RESET SWITCH ON

Next: !p868, !f915

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: !p953, !f954

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: !p957, !f958

RESISTANCE DISPLAY PCB UNIVERSAL

THERMOSTAT TO MAX PO

Next: !p973, !f974

GAS INLET PRESSURE

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
MAINS RESET SWITCH ON

Next: p1256, !f982

OBSERVATION DOES FAN RUN BEFORE FAULT

ENSURE BOILER IS COOL
TEMPERATURE CONTROL TO MINIMUM (FULLY ANTI-CLOCKWISE)

Next: p1012, ?1014, ?1016

VOLTAGE FAN HALL SENSOR

GAIN ACCESS TO PCB

Next: !p1024, !f1025

FAN VOLTAGE

{MAINSRSSWOFF}
SET TEMPERATURE CONTROL TO MAXIMUM

Next: p1020, !f1021

VOLTAGE FAN SPEED CONTROL

GAIN ACCESS TO PCB
USE INSULATION MAT AS REQUIRED

Next: !p1018, !f1019

VOLTAGE FAN CONTROL (FAULT CODE F3)

{MAINSRSSWOFF}
SET TEMPERATURE CONTROL TO MAXIMUM

Next: !p1494, ?1495, ?1497

RESISTANCE GAS VALVE AND HARNESS

{MAINSRSSWOFF}
REMOVE THE CONNECTOR J1 FROM THE PCB

Next: p1036, f1037

RESISTANCE SPARK GENERATOR AND HARNESS

REMOVE REAR CONTROL PANEL COVER TO EXPOSE MAIN PCB
REMOVE CONNECTOR H2 FROM MAIN PCB

Next: !p1040, f1041

RESISTANCE GAS VALVE AND HARNESS IRIS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: p1045, f1046

RESISTANCE SPARK GENERATOR AND HARNESS IRIS

REMOVE REAR CONTROL PANEL COVER TO EXPOSE MAIN PCB
REMOVE CONNECTOR H2 FROM MAIN PCB

Next: p1049, f1050

RESISTANCE DC FAN CONTROLLER

DISCONNECT FAN DC CONTROLLER CONNECTOR MARKED H3 ON THE MAIN PCB.

Next: !p1053, !f1054

IDENTIFY PCB

REMOVE CONTROL BOX COVER

Next: p1088, f1089

VOLTAGE TO MAIN PCB IRIS

Next: p1112, f1113

FUSE F1 (RES) SYMS

REMOVE FUSE F1 FROM ITS HOLDER ON THE MAIN PCB

Next: p1148, f1099

FUSE F1 (RES) IRIS

REMOVE FUSE F1 FROM ITS HOLDER ON THE MAIN PCB

Next: p1552, f1121

REMOVE FAN CONNECTOR SYMS

{MAINSRSSWOFF}
REMOVE J4 CONNECTOR FROM THE PCB AND PLACE IT SAFELY AWAY FROM THE BOARD

Next: p1149, f1444

MAIN PCB TO DISPLAY PCB VOLTS

{MAINSRSSWOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p1151, !f1152

RESISTANCE HARNESS USER INTERFACE

REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB

Next: !p1153, !f1154

PUMP LIMPET TEST (CH)

Next: p1676, !f1168

TYPE OF FAN CONTROL

THERE ARE THREE TYPE

Next: p1198, ?1199, ?1201

FAN VOLTAGE

{MAINSRSSWOFF}
SET TEMPERATURE CONTROL TO MAXIMUM

Next: p1241, f1242

FAN VOLTAGE

{MAINSRSSWOFF}
SET TEMPERATURE CONTROL TO MAXIMUM

Next: p1223, f1224

IS MOD CARD PRESENT

{MAINSRSSWOFF}

Next: p1203, !f1204

FAN VOLTAGE

{MAINSRSSWOFF}
SET TEMPERATURE CONTROL TO MAXIMUM

Next: p1205, f1206

VOLTAGE FAN CONTROL

{MAINSRSSWOFF}
SET TEMPERATURE CONTROL TO MAXIMUM

Next: p1209, ?1434, ?1436

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: p1211, !f1212

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: p1213, !f1214

OVERHEAT THERMOSTAT

DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT

Next: p1215, !f1216

OBSERVATION DISPLAY PCB TYPE

RELEASE THE FRONT FASCIA BY GENTLY PRISING UP THE RETAINING LATCHES AT THE TOP OF THE FACIA

Next: p1217, f1218

DISPLAY PCB POT

SET TEMPERATURE SELE

Next: !p1559, !f1222

VOLTAGE FAN CONTROL

{MAINSRSSWOFF}
SET TEMPERATURE CONTROL TO MAXIMUM

Next: p1227, ?1440, ?1442

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: p1229, !f1230

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: p1231, !f1232

OVERHEAT THERMOSTAT

DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT

Next: p1233, !f1234

OBSERVATION DISPLAY PCB TYPE

RELEASE THE FRONT FASCIA BY GENTLY PRISING UP THE RETAINING LATCHES AT THE TOP OF THE FACIA

Next: p1235, f1236

DISPLAY PCB POT

SET TEMPERATURE SELE

Next: !p1557, !f1240

FAN TEST (DISCONNECTED)

DISCONNECT CONNECTOR MARKED J4 FROM THE
MAIN PCB AND MAKE SAFE

Next: !p1245, f1246

CONDENSATE SIPHON

Next: p1257, !f1258

ELECTRODE LEAD INSPECTION

REMOVE THE ELECTRODE LEAD FROM THE BOILER

Next: p1259, !f1260

SPARK ELECTRODE

REMOVE ELECTRODE ASSEMBLY

Next: p1711, !f1262

PUMP LIMPET TEST (DHW)

Next: p134, !f135

EXTERNAL CONTROLS DHW DEMAND

Next: !p136, !f137

EXTERNAL PUMP RUNS (CH)

MAINS RESET SWITCH ON

Next: p159, f160

INSPECTION PCB CAPACITORS

{MAINSRSSWOFF}

Next: p1573, !f1451

EXTERNAL BYPASS

Next: p950, !f1489

RESISTANCE THERMISTOR FLOW AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: p1500, f1501

RESISTANCE THERMISTOR RETURN AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: !p1502, f1503

IDENTIFY PCB

REMOVE CONTROL BOX COVER

Next: p1515, f1516

RESISTANCE HARNESS USER INTERFACE

REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB

Next: p1519, !f1520

RESISTANCE DISPLAY PCB (IRIS MAIN PCB)

REMOVE THE CONNECTOR FROM THE DISPLAY PCB
REMOVE THE DISPLAY PCB FROM THE FACIA

Next: !p1588, !f1522

OBSERVATION BOILER RESET F13 FAULT

ON/OFF SWITCH ON

Next: !p1551, f1540

INSPECTION PCB CAPACITORS

{MAINSRSSWOFF}

Next: p1580, !f1544

RESISTANCE HARNESS USER INTERFACE

REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB

Next: p1553, !f1554

RESISTANCE DISPLAY PCB (IRIS MAIN PCB)

REMOVE THE CONNECTOR FROM THE DISPLAY PCB
REMOVE THE DISPLAY PCB FROM THE FACIA

Next: !p1555, !f1556

IDENTIFY PCB

REMOVE CONTROL BOX COVER

Next: p1574, f1575

RESISTANCE DISPLAY PCB (IRIS MAIN PCB)

REMOVE THE CONNECTOR FROM THE DISPLAY PCB
REMOVE THE DISPLAY PCB FROM THE FACIA

Next: !p1578, !f1579

IDENTIFY PCB

REMOVE CONTROL BOX COVER

Next: p1581, f1582

RESISTANCE DISPLAY PCB (IRIS MAIN PCB)

REMOVE THE CONNECTOR FROM THE DISPLAY PCB
REMOVE THE DISPLAY PCB FROM THE FACIA

Next: !p1585, !f1586

PUMP LIMPET TEST (CH)

Next: p163, !f164

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: p1605, !f1606

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: p1607, !f1608

OBSERVATION DISPLAY PCB TYPE

RELEASE THE FRONT FASCIA BY GENTLY PRISING UP THE RETAINING LATCHES AT THE TOP OF THE FACIA

Next: p1609, f1610

DISPLAY PCB POT

SET TEMPERATURE SELE

Next: !p1613, !f1614

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: p1616, !f1617

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: p1618, !f1619

OVERHEAT THERMOSTAT

DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT

Next: p1620, !f1621

FLUE CHECK

Next: p1622, !f1623

CONDENSATE SIPHON

Next: p1624, !f1625

OBSERVATION DISPLAY PCB TYPE

RELEASE THE FRONT FASCIA BY GENTLY PRISING UP THE RETAINING LATCHES AT THE TOP OF THE FACIA

Next: p1626, f1627

DISPLAY PCB POT

SET TEMPERATURE SELE

Next: !p1630, !f1631

EXTERNAL BYPASS

Next: !p165, !f166

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: p1633, !f1634

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: p1635, !f1636

OBSERVATION DISPLAY PCB TYPE

RELEASE THE FRONT FASCIA BY GENTLY PRISING UP THE RETAINING LATCHES AT THE TOP OF THE FACIA

Next: p1637, f1638

DISPLAY PCB POT

SET TEMPERATURE SELE

Next: !p1641, !f1642

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: p1644, !f1645

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: p1646, !f1647

OVERHEAT THERMOSTAT

DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT

Next: p1648, !f1649

FLUE CHECK

Next: p1650, !f1651

CONDENSATE SIPHON

Next: p1652, !f1653

OBSERVATION DISPLAY PCB TYPE

RELEASE THE FRONT FASCIA BY GENTLY PRISING UP THE RETAINING LATCHES AT THE TOP OF THE FACIA

Next: p1654, f1655

DISPLAY PCB POT

SET TEMPERATURE SELE

Next: !p1658, !f1659

CH TEST TEMPERATURE

TURN CH THERMOSTAT U

Next: !p1661, ?1662, ?1664, ?1666

EXTERNAL BYPASS

Next: !p1674, !f1675

OBSERVATION DISPLAY PCB TYPE

RELEASE THE FRONT FASCIA BY GENTLY PRISING UP THE RETAINING LATCHES AT THE TOP OF THE FACIA

Next: p1668, f1669

DISPLAY PCB POT

SET TEMPERATURE SELE

Next: !p1672, !f1673

FLOW THERMISTOR

REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR

Next: p1677, !f1678

RETURN THERMISTOR

DISCONNECT WHITE WIRES FROM THE THERMISTOR

Next: p1679, !f1680

CH TEST TEMPERATURE

TURN CH THERMOSTAT U

Next: !p1681, ?1683, ?1685, ?1687

EXTERNAL BYPASS

Next: !p1695, !f1696

OBSERVATION DISPLAY PCB TYPE

RELEASE THE FRONT FASCIA BY GENTLY PRISING UP THE RETAINING LATCHES AT THE TOP OF THE FACIA

Next: p1689, f1690

DISPLAY PCB POT

SET TEMPERATURE SELE

Next: !p1693, !f1694

INSPECTION FLUE

Next: p1705, !f1706

BURNER

Next: p1707, !f1708

INSPECTION HEAT EXCHANGER FLUEWAYS

{MAINSRSSWOFF}
REMOVE FAN, GAS VALVE AND BURNER ASSEMBLY

Next: !p1709, !f1710

INSPECTION HEAT EXCHANGER FLUEWAYS

{MAINSRSSWOFF}
REMOVE FAN, GAS VALVE AND BURNER ASSEMBLY

Next: p1712, !f1713

FLUE CHECK

Next: p1714, !f1715

RESET GAS VALVE

RESET GAS VALVE THRO

Next: p1716, !f1717

CONDENSATE SIPHON

Next: p1771, !f1770

INSPECTION FLUE

Next: p1773, !f1772

PRESSURE GAS INLET AND DIP

ATTACH PRESSURE GAUG

Next: p1774, ?1775, ?1777

SPARK ELECTRODE

REMOVE ELECTRODE ASSEMBLY

Next: p1783, !f1784

GAS VALVE VOLTAGE

SET TEMPERATURE SELE

Next: !p1779, f1780

INSPECTION HEAT EXCHANGER FLUEWAYS

{MAINSRSSWOFF}
REMOVE FAN, GAS VALVE AND BURNER ASSEMBLY

Next: p1785, !f1786

BURNER

Next: !p1787, !f1788

RESISTANCE THERMISTOR RETURN AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: !p334, f335

DOES PUMP RUN

Next: p366, f367

PUMP LIMPET TEST (CH)

Next: p918, !f371

PUMP LIMPET TEST (CH)

Next: p410, !f411

RESISTANCE THERMISTOR FLOW AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: p412, f413

RESISTANCE THERMISTOR RETURN AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: p1660, f417

OVERHEAT THERMOSTAT

DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT

Next: !p515, !f516

VOLTAGE CONTROLS PCB DEMAND

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
USE INSULATION MAT AS REQUIRED

Next: p1197, ?562, ?564

EXTERNAL CONTROLS VOLTAGE (OUTPUT)

{MAINSRSSWOFF}
RE

Next: !p566, !f744

VOLTAGE TO MAIN PCB IRIS

Next: !p779, !f780

RESISTANCE PUMP AND HARNESS IRIS

REMOVE REAR CONTROL

Next: p1044, f1159

RESISTANCE PUMP AND HARNESS

REMOVE REAR CONTROL

Next: p1035, f1155

SPARK GENERATOR (OUTPUT)

ENSURE THE APPLIANCE

Next: p866, f867

INSPECTION PCB AND CONNECTIONS

Next: !p916, !f917

SPARK ELECTRODE

REMOVE ELECTRODE ASSEMBLY

Next: !p870, !f871

OBSERVATION PUMP OVERRUN

Next: p1459, !f979

RESISTANCE THERMISTOR FLOW AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: p951, f952

RESISTANCE THERMISTOR RETURN AND HARNESS

REMOVE THE CONNECTOR J1 FROM THE PCB

Next: p955, f956

CH TEST TEMPERATURE

TURN CH THERMOSTAT U

Next: !p959, ?961, ?963, ?965, ?967

OBSERVATION DISPLAY PCB TYPE

RELEASE THE FRONT FASCIA BY GENTLY PRISING UP THE RETAINING LATCHES AT THE TOP OF THE FACIA

Next: p971, f972

THERMOSTAT OVERHEAT - OVERHEAT THERMOSTAT

DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT

Next: !p969, !f970

EXTERNAL PUMP RUNS (DHW)

MAINS RESET SWITCH ON

Next: p130, f131

DISPLAY PCB POT

SET TEMPERATURE SELE

Next: !p975, !f976

System Information

  • Total Tests: 522
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control