Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Measurement:
Test 1:
Measure the resistance across pump L (marked PL) and N (marked PN)
Resistance will vary by pump but should be above 80 Ohms.
Test 2:
Measure the resistance across pump L (marked PL) and a suitable earth.
Resistance should be greater than 1Mohm.
Test 3:
Measure the resistance across pump N (marked PN) and a suitable earth.
Resistance should be greater than 1Mohm.
Measure the resistance across pump L (marked PL) and N (marked PN)
Resistance will vary by pump but should be above 80 Ohms.
Test 2:
Measure the resistance across pump L (marked PL) and a suitable earth.
Resistance should be greater than 1Mohm.
Test 3:
Measure the resistance across pump N (marked PN) and a suitable earth.
Resistance should be greater than 1Mohm.