Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
START UP DISPLAY
ENSURE NO DEMANDS
SELF CHECK AND APPLIANCE SET UP
ENSURE NO DEMANDS
OBSERVATION FAN RUNS CH DEMAND
BOILER CH THERMOSTAT SET TO MAX
ENSURE CH SYSTEM IS COOL
OBSERVATION BURNER IGNITION AND ESTABLISH
BOILER CH THERMOSTAT SETTING TO MAX
HEADER FOR FLOW THERMISTOR FAULT CODE
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR RETURN THERMISTOR FAULT CODE
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F70 FAULT CODE
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F64, F71, F84 AND F85
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F61 AND F88
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F49
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F86
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR FAULT CODE CON OR ERR
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F67 AND F87
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F62 AND F27
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F29
INTENTIONALLY BLANK HEADER FOR FAULT CODE
FAULT CODE HISTORY GUIDE
RESET THE APPLIANCE
HEADER FOR FUSE INVESTIGATION
INTENTIONALLY BLANK HEADER FOR FUSE INVESTIGATION
OPERATION PUMP OVERRUN
LOCATE PUMP ON SYSTEM
OPERATION DHW
CH DEMAND OFF
DHW DEMAND ON
CIRCULATION OR THERMISTOR ISSUES ON CH
INTENTIONALLY BLANK HEADER FOR CH ISSUES - THERMISTOR / CIRCULATION RELATED
INFORMATION FOR OBSERVATION ADJUSTMENT DSN DISPLAY OPERATES
THE PCB'S OPERATING
QUICK ACCESS DATA AND INFORMATION
THE TABLE BELOW SHOW
LITE DIAGNOSTIC
DIAGNOSIS RELIES ON
HEADER FOR QADAI FLOW THERMISTOR
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR QADAI RETURN THERMISTOR
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR QADAI GAS VALVE RESISTANCE
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR QADAI GAS VALVE VOLTAGE
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR QADAI AC VOLTAGE TO PUMP
INTENTIONALLY BLANK HEADER FOR FAULT CODE
RESTRICTED OR BLOCKED FLUEWAYS
HEAT EXCHANGER
WEAK OR SLOW
PUMP
INCORRECTLY SET 3
PARAMETER DSN
LOW 3
GAS INLET PRESSURE
POOR CH OPERATION
THERMISTOR FITMENT
POOR CH OPERATION
SENSOR
POOR CH OPERATION
SENSOR
NO POWER TO PUMP
PCB
FUSE INVESTIGATION
PUMP
AIR OR LOW PRESSURE 3
REFILL AND VENT
AIR OR LOW PRESSURE 4
REFILL AND VENT
AIR OR LOW PRESSURE
REFILL AND VENT
OVERHEAT
PCB
FAULTY FAN SECTION 2
HARNESS HEAT ENGINE
FAN CIRCUITRY RUNNING CONTINUOUSLY
FAN C/W COMBUSTION CHAMBER COVER
RESTRICTED CAUSING LOW GAS RATE
DUCT - AIR INLET
AIR INTAKE RESTRICTED OR BLOCKED 2
FAN C/W COMBUSTION CHAMBER COVER
POOR OUTPUT
SYPHON
POOR OUTPUT
FLUE
POOR OUTPUT
BURNER
POOR OUTPUT
HEAT EXCHANGER
INCORRECTLY SET 2
PARAMETER DSN
BLANK FOR TYPE OF DIAGNOSITC PROCEDURE
Z REDIRECTION
RESTRICTED CAUSING LOW GAS RATE OVERHEAT
DUCT - AIR INLET
AIR INTAKE RESTRICTED OR BLOCKED OVERHEAT
FAN C/W COMBUSTION CHAMBER COVER
POOR OUTPUT OVERHEAT
SYPHON
POOR OUTPUT OVERHEAT
FLUE
POOR OUTPUT OVERHEAT
BURNER
POOR OUTPUT OVERHEAT
HEAT EXCHANGER
CAUSING ODD DISPLAY
FAN C/W COMBUSTION CHAMBER COVER
SHORTING ODD DISPLAY
HARNESS HEAT ENGINE
NO DISPLAY
PCB
FAULTY
HARNESS WIRING
FAULTY FAN SECTION 3
HARNESS HEAT ENGINE
FAULTY FAN SECTION 3 FAULT CODE
HARNESS HEAT ENGINE
THERMISTOR WAITING TIME
THERMISTOR FITMENT
THERMISTOR WAITING TIME
SENSOR
THERMISTOR WAITING TIME
SENSOR
AIR OR LOW PRESSURE 2
REFILL AND VENT
NO DEMAND TO RUN FAN
SENSOR
NO DEMAND TO RUN FAN
SENSOR
FAULTY FAN SECTION
HARNESS HEAT ENGINE
BLANK INFORMATION PAGE FOR DSN ADJUSTMENT
Z REDIRECTION
BLANK FOR QADAI
Z REDIRECTION
BLANK FOR LITE DIAGNOSTIC
Z REDIRECTION
QADAI
SENSOR
QADAI
SENSOR
QADAI
GAS CONTROL VALVE
CASE OFF
Z REDIRECTION
SELF TEST 3
PCB
RESTRICTED OR BLOCKED
SYPHON
LOW
GAS INLET PRESSURE
RESTRICTED OR BLOCKED / POORLY SEALED
DUCT - AIR INLET
RESTRICTED OR BLOCKED / POORLY SEALED 2
DUCT - AIR INLET
RESTRICTED / BLOCKED
BURNER
WARPED OR HIGH RESISTANCE
ELECTRODE IGNITION AND SENSING
SECTION TO SPARK GENERATOR 2
HARNESS HEAT ENGINE
RESTRICTED OR BLOCKED FLUEWAYS 2
HEAT EXCHANGER
NO SPARK OR WARPED
ELECTRODE IGNITION AND SENSING
SECTION TO SPARK GENERATOR
HARNESS HEAT ENGINE
RESTRICTED OR BLOCKED / [POORLY SEALED 3
DUCT - AIR INLET
RESTRICTED OR BLOCKED 2
BURNER
RESTRICTED OR BLOCKED FLUEWAYS 3
HEAT EXCHANGER
GAS VALVE DAMAGED PCB
GAS CONTROL VALVE AND PCB
LOW 2
GAS INLET PRESSURE
RESTRICTED OR BLOCKED 2
SYPHON
INCORRECTLY SET
PARAMETER - HEATING POWER
OUT OF CALIBRATION 2
SENSOR
OUT OF CALIBRATION 2
SENSOR
BLANK FOR FAULT CODES 2
Z REDIRECTION
NO DISPLAY
FUSE (FUSED SPUR)
NO DISPLAY
FUSE PCB
BLANK FOR HEATING POWER DIAGNOSTIC CODES
Z REDIRECTION
FAULT CODE
SENSOR
FAULT CODE
SENSOR
INCORRECTLY SET
PARAMETER DSN
FAULT CODE THERMISTOR ISSUES
SENSOR
FAULT CODE THERMISTOR ISSUES
SENSOR
FAULT CODE F64 AND F71
THERMISTOR FITMENT
OVERHEAT
THERMISTOR FITMENT
OVERHEAT
SENSOR
OVERHEAT
SENSOR
FAULT CODE
GAS CONTROL VALVE
F49 FAULT CODE
PCB
FAULT CODE
EBUS CONTROLS
MISSING
LINK
FAULT CODE F86
UNDERFLOOR HEATING CONTROLS
FAULT CODE F87
ELECTRODE IGNITION AND SENSING
ERROR CODE
HARNESS WIRING
FAULT CODE F62 AND F27
ELECTRODE IGNITION AND SENSING
PASSING WITH FAN PRESSURE
GAS CONTROL VALVE
PASSING WITH NO FAN PRESSURE
GAS CONTROL VALVE
FAULT CODE F29
DUCT - AIR INLET
FAULT CODE F29
ELECTRODE IGNITION AND SENSING
FAULT CODE F29
HARNESS HEAT ENGINE
FAULT CODE F29
FLUE
FAULT CODE F29
BURNER
FAULT CODE F29
HEAT EXCHANGER
FAULT CODE F29
SYPHON
FAULT CODE F29
GAS INLET PRESSURE
BLANK FOR UNRECORDED FAULT 2
Z REDIRECTION
BLANK FOR FAULT CODE HISTORY
Z REDIRECTION
LEAKING
FLUE PIPE GASKETS
BAFFLING WRONG MIX
GAS CONTROL VALVE
CH DOES NOT RESPOND
EBUS CONTROLS
NOT RUNNING
PUMP
NOT RUNNING 2
PUMP
NOT RUNNING OVERHEAT
PUMP
BLANK FOR OVERHEAT
Z REDIRECTION
CORRECTLY ACTIVATED
FROST PROTECTION
POOR OUTPUT
GAS CONTROL VALVE
POOR OUTPUT OVERHEAT
GAS CONTROL VALVE
PCB BLOWING FUSE
PCB FUSE BLOWN
DISPLAY ODD
PCB
FAULTY
DISPLAY
NOT RUNNING WITH DEMAND
FAN C/W COMBUSTION CHAMBER COVER
HARD RESET PCB
HARD RESET PCB
FLOW THERMISTOR SATISFACTORY
RESULT AS EXPECTED
RETURN THERMISTOR SATISFACTORY
RESULT AS EXPECTED
GAS VALVE TOP SOLENOID
RESULT AS EXPECTED
PCB GAS VALVE VOLTAGE TOP SOLENOID
RESULT AS EXPECTED
PCB POWER TO PUMP AC
RESULT AS EXPECTED
SELF TEST
EBUS CONTROLS
NOT ESTABLISHING WRONG MIX
GAS CONTROL VALVE
RESTRICTED OR BLOCKED
PIPE - FLUE
RESTRICTED OR BLOCKED 2
DRAIN - CONDENSATE (SUMP)
RESTRICTED OR BLOCKED
FLUE PIPE GASKETS
NOT RECTIFYING
IGNITOR / SPARK GENERATOR
LOW FAN PRESSURE
FAN C/W COMBUSTION CHAMBER COVER
FAULTY HALL SENSOR
FAN C/W COMBUSTION CHAMBER COVER
NO SPARK
IGNITOR / SPARK GENERATOR
NOT IGNITING WRONG MIX
GAS CONTROL VALVE
RESTRICTED OR BLOCKED 2
PIPE - FLUE
RESTRICTED OR BLOCKED 3
DRAIN - CONDENSATE (SUMP)
RESTRICTED OR BLOCKED 2
FLUE PIPE GASKETS
LOW FAN PRESSURE NOT IGNITING
FAN C/W COMBUSTION CHAMBER COVER
NOT IGNITING NOT OPENING
GAS CONTROL VALVE
HARNESS DAMAGED GAS VALVE
HARNESS HEAT ENGINE AND PCB
FAULTY HALL SENSOR FAULT CODE
FAN C/W COMBUSTION CHAMBER COVER
BLANK FOR FAULT CODES 1
Z REDIRECTION
FUSE FURTHER INVESTIGATION
Z REDIRECTION
FUSE FURTHER INVESTIGATION 2
Z REDIRECTION
FLOW THERMISTOR SECTION
HARNESS HEAT ENGINE
RETURN THERMISTOR SECTION
HARNESS HEAT ENGINE
F70 FAULT CODE
PCB
FAULT CODE THERMISTOR ISSUES
HARNESS HEAT ENGINE
FAULT CODE THERMISTOR ISSUES 2
HARNESS HEAT ENGINE
FAULT CODE GAS VALVE
HARNESS HEAT ENGINE
F49 FAULT CODE 2
PCB
F86 FAULT CODE
PCB
F86 FAULT CODE 2
PCB
CONNECTION FAULT CODE
DISPLAY
F87 FAULT CODE
PCB
FAULT CODE F29
PCB
FAULT CODE F29
IGNITOR / SPARK GENERATOR
FAULT CODE F29
GAS CONTROL VALVE
FAULT CODE F29
PIPE - FLUE
FAULT CODE F29
DRAIN - CONDENSATE (SUMP)
FAULT CODE F29
FLUE PIPE GASKETS
LOW FAN PRESSURE FAULT CODE F29
FAN C/W COMBUSTION CHAMBER COVER
BLANK FOR UNRECORDED FAULT
Z REDIRECTION
RESTRICTED OR PERFORATED
PIPE - FLUE
RESTRICTED OR BLOCKED
DRAIN - CONDENSATE (SUMP)
24 VOLT EXTERNAL CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION EXTERNAL CONTROLS FITTED
EBUS CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION EXTERNAL CONTROLS FITTED
APPLIANCE DOES NOT RECOGNISE DHW DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
APPLIANCE RECOGNISES DHW DEMAND BUT OPERATION UNSATISFACTORY
CHARACTERISTIC TEST FROM OPERATION DHW
CH DEMAND RECOGNISED BUT SYMBOLS AND TEMPERATURE RANDOMLY CHANGING
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS CH DEMAND
CH DEMAND RECOGNISED BUT FAN DOES NOT RUN OR ONLY RUNS FOR UP TO 10 SECONDS
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS CH DEMAND
DISPLAY ILLUMINATES BUT GOES OFF AFTER APPROXIMATELY 15 SECONDS
CHARACTERISTIC TEST FROM START UP DISPLAY
CH DEMAND NOT RECOGNISED
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS CH DEMAND
FAN RUNS CONTINUOUSLY AT HIGH SPEED
CHARACTERISTIC TEST FROM SELF CHECK AND APPLIANCE SET UP
RADIATOR SYMBOL FLASHES IN DISPLAY
CHARACTERISTIC TEST FROM SELF CHECK AND APPLIANCE SET UP
BURNER DOES NOT IGNITE AND ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
BURNER IGNITES BUT BAFFLES OR IS NOISY
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
FAULT CODE F32 SHOWN
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
BOILER REACHES TEMP RADIATORS REMAIN COOL OR DO NOT HEAT
CHARACTERISTIC TEST FROM OPERATION CENTRAL HEATING
BOILER AND RADIATORS FAIL TO REACH SET TEMPERATURE
CHARACTERISTIC TEST FROM OPERATION CENTRAL HEATING
FAULT CODE SHOWN
CHARACTERISTIC TEST FROM START UP DISPLAY
DISPLAY DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM START UP DISPLAY
PREVIOUSLY UNRECORDED FAULT SHOWN
CHARACTERISTIC TEST FROM START UP DISPLAY
22/12/2022 12:19:37 2211_1_50_1 27/01/2023 11:04:47
16/01/2023 08:10:48
OBSERVATION THERMISTORS CORRECTLY FITTED
REMOVE AIR INTAKE TUBE TO GAIN ACCESS TO FLOW THERMISTOR
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE PUMP AT PCB
{GAINPCBACS}
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
OBSERVATION THERMISTORS CORRECTLY FITTED
REMOVE AIR INTAKE TUBE TO GAIN ACCESS TO FLOW THERMISTOR
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE THERMISTOR FLOW
REMOVE AIR INTAKE TUBE TO GAIN ACCESS
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR FLOW
REMOVE AIR INTAKE TUBE TO GAIN ACCESS
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
RESISTANCE GAS VALVE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE
VOLTAGE PUMP AT PCB
{GAINPCBACS}
OBSERVATION EXTERNAL CONTROLS FITTED - SELF TEST
GAIN ACCESS TO PCB
DISCONNECT EBUS CONTROLS - SELF TEST
REMOVE EBUS WIRING CONNECTIONS AND MAKE SAFE
REMOVE WIRE LINK BETWEEN THE 24 VOLT CONNECTIONS
VOLTAGE RECTIFICATION AT PCB
{GAINPCBACS}
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
INSPECTION FLUE PIPE AND SUMP / GASKETS
REMOVE THE FLUE PIPE FROM FRONT OF THE APPLIANCE
RESISTANCE HARNESS SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND CONNECTOR X21 FROM THE PCB
VOLTAGE SPARK GENERATOR AT PCB
{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND MAKE SAFE
VOLTAGE FAN HALL SENSOR AT PCB
{GAINPCBACS}
RESISTANCE HARNESS FAN
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
INSPECTION FLUE PIPE AND SUMP / GASKETS
REMOVE THE FLUE PIPE FROM FRONT OF THE APPLIANCE
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE GAS VALVE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE
RESISTANCE HARNESS FAN
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE FUSE (FUSED SPUR)
REMOVE FUSE FROM FUSED SPUR
FUSE FURTHER INVESTIGATION (FUSED SPUR)
THE INFORMATION PROV
FUSE FURTHER INVESTIGATION (PCB FUSE)
THE INFORMATION PROV
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR FLOW
REMOVE AIR INTAKE TUBE TO GAIN ACCESS
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
OBSERVATION THERMISTORS CORRECTLY FITTED
REMOVE AIR INTAKE TUBE TO GAIN ACCESS TO FLOW THERMISTOR
RESISTANCE THERMISTOR FLOW
REMOVE AIR INTAKE TUBE TO GAIN ACCESS
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
OBSERVATION THERMISTORS CORRECTLY FITTED
REMOVE AIR INTAKE TUBE TO GAIN ACCESS TO FLOW THERMISTOR
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE GAS VALVE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE
VOLTAGE DISPLAY AT MAIN PCB
{GAINPCBACS}
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
RESISTANCE HARNESS SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND CONNECTOR X21 FROM THE PCB
INSPECTION FLUE PIPE AND SUMP / GASKETS
REMOVE THE FLUE PIPE FROM FRONT OF THE APPLIANCE
RESISTANCE PUMP AND HARNESS AC FUSE INVESTIGATION
REMOVE CONNECTOR X14 FROM THE PCB
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
OBSERVATION EXTERNAL CONTROLS FITTED
GAIN ACCESS TO THE PCB
BYPASS EXTERNAL CONTROLS - 240V
DISCONNECT 240V EXTE
BYPASS EXTERNAL CONTROLS - 24V
DISCONNECT 24V EXTER
DISCONNECT EBUS CONTROLS - CH DEMAND
DISCONNECT EBUS WIRING CONNECTIONS AND MAKE SAFE
PRESSURE GAS VALVE INLET
ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT
RESISTANCE THERMISTOR FLOW
REMOVE AIR INTAKE TUBE TO GAIN ACCESS
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
OBSERVATION PUMP RUNNING
LOCATE SYSTEM PUMP
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE C
OBSERVATION PUMP RUNNING
LOCATE SYSTEM PUMP
OBSERVATION PUMP RUNNING
LOCATE SYSTEM PUMP
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE C
OBSERVATION RUN BOILER TO TEMPERATURE
BOILER CH THERMOSTAT
OPERATION PUMP OVERRUN FOR OVERHEAT
LOCATE SYSTEM PUMP
RESISTANCE THERMISTOR FLOW
REMOVE AIR INTAKE TUBE TO GAIN ACCESS
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
RESISTANCE HARNESS FAN
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
INSPECTION FAN INTAKE
REMOVE THE AIR INTAKE DUCT FROM THE FAN ASSEMBLY
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
INSPECTION FAN INTAKE
REMOVE THE AIR INTAKE DUCT FROM THE FAN ASSEMBLY
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
OBSERVATION DISCONNECT FAN ASSEMBLY - DISPLAY NORMAL?
REMOVE CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
RESISTANCE HARNESS FAN
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
VOLTAGE DISPLAY AT MAIN PCB
{GAINPCBACS}
RESISTANCE HARNESS DISPLAY PCB
REMOVE CONNECTOR X51 FROM THE PCB
REMOVE CONNECTOR FROM THE DISPLAY PCB
VOLTAGE DC FAN PERMANENT
{GAINPCBACS}
RESISTANCE THERMISTOR FLOW
REMOVE AIR INTAKE TUBE TO GAIN ACCESS
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
OBSERVATION PUMP RUNNING
LOCATE SYSTEM PUMP
TEMPERATURE DIFFERENTIAL CH NOT FIRING
ATTACH TEMPERATURE C
VOLTAGE DC FAN DEMAND
{GAINPCBACS}
REMOVE 4 WIRE CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
RESISTANCE HARNESS FAN
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
OBSERVATION ADJUSTMENT DSN DISPLAY OPERATES CORRECTLY
REMOVE CONNECTOR FROM RETURN THERMISTOR AND MAKE SAFE
DISCONNECT EXTERNAL CONTROLS
REMOVE ALL EXTERNAL
PRESSURE GAS VALVE INLET
ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
PRESSURE GAS VALVE INLET
ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT
PRESSURE FAN
NO DEMANDS
ATTACH TUBE FROM + VE CONNECTION ON FGA TO THE UPPER GAS VALVE TEST POINT
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
PRESSURE FAN
NO DEMANDS
ATTACH TUBE FROM + VE CONNECTION ON FGA TO THE UPPER GAS VALVE TEST POINT
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
RESISTANCE SPARK GENERATOR AND HARNESS
REMOVE IGNITION ELECTRODE LEAD FROM
TERMINAL 3 OF THE SPARK GENERATOR
PRESSURE FAN - EQUALISATION
NO DEMANDS
ATTACH TUBE FROM + VE CONNECTION ON FGA TO THE UPPER GAS VALVE TEST POINT
OBSERVATION SPARKING
DISCONNECT THE IGNIT
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
RESISTANCE HARNESS SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND CONNECTOR X21 FROM THE PCB
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
VOLTAGE FAN HALL SENSOR AT PCB
{GAINPCBACS}
OBSERVATION MAXIMUM HEATING POWER
NO DEMANDS
RESISTANCE THERMISTOR FLOW
REMOVE AIR INTAKE TUBE TO GAIN ACCESS
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
VOLTAGE MAINS POWER INPUT AT PCB
{GAINPCBACS}
RESISTANCE FUSE PCB
REMOVE FUSE FROM PCB
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR FLOW
REMOVE AIR INTAKE TUBE TO GAIN ACCESS
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
OBSERVATION DISCONNECT EBUS CONTROLS
REMOVE THE EBUS WIRING AND MAKE SAFE
OBSERVATION LINK UNDERFLOOR HEATING CONTROL
REMOVE WIRES FROM TO
RESISTANCE HARNESS DISPLAY PCB
REMOVE CONNECTOR X51 FROM THE PCB
REMOVE CONNECTOR FROM THE DISPLAY PCB
PRESSURE STANDING RETURN
ATTACH U-GAUGE TO INLET PRESSURE TEST POINT
ENSURE NO OTHER GAS APPLIANCES ARE IN OPERATION
PRESSURE GAS VALVE INLET
ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT
VOLTAGE RECTIFICATION AT PCB FAULT CODE
{GAINPCBACS}
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
RESISTANCE SPARK GENERATOR AND HARNESS
REMOVE IGNITION ELECTRODE LEAD FROM
TERMINAL 3 OF THE SPARK GENERATOR
PRESSURE FAN
NO DEMANDS
ATTACH TUBE FROM + VE CONNECTION ON FGA TO THE UPPER GAS VALVE TEST POINT
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
ACCESS PREVIOUSLY UNRECORDED
IF A NEW FAULT OCCUR
INSPECTION FLUE PIPE AND SUMP / GASKETS
REMOVE THE FLUE PIPE FROM FRONT OF THE APPLIANCE
System Information
- Total Tests: 444
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control