Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the DC voltage between each of the pins on connector X51 and an earth (use the copper pipe to the gas valve as earth).
Expected voltages are as per the table below:
PinDC Volts
14.8
2 22.5
34.9
421.7
54.9
60

Are the voltages measured as expected?