Parameter DSN Number Procedure
• Press for more than 7 seconds on the MODE button to access the configuration menu. The screen displays "0".
• Press on button + or - under the symbol       and navigate to number 35.
• Press on MODE to validate. The screen displays the parameter "d.00" and its value "XX”.
• Press on button + or - under the symbol       to access the parameter d.93.
• Press on button + or - under the symbol       if required to modify the value of the parameter to 12 SXI = 18, 18 SXI = 19, 30 SXI = 20.
• If parameter has been altered allow setting to stop flashing.
• Press for more than 3 seconds on the button MODE to exit the configuration menu.