Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X2 from the PCB
Measurement:
Test 1.
Measure the resistance between pin 3 (brown)
on X2 to pin 2 (blue) wire at X1 on the PCB.
Expected resistance greater than 1 MOhm (or O.L).
Test 2.
Measure for resistance between pin 3 (brown)
on X2 to a suitable earth connection.
Expected resistance greater than 1 MOhm (or O.L).
Measure the resistance between pin 3 (brown)
on X2 to pin 2 (blue) wire at X1 on the PCB.
Expected resistance greater than 1 MOhm (or O.L).
Test 2.
Measure for resistance between pin 3 (brown)
on X2 to a suitable earth connection.
Expected resistance greater than 1 MOhm (or O.L).

Isolate as per TOPs P4
and refit as necessary