Set Appliance State:
Gas Off
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
CH temperature selector to 0 position
DHW temperature selector to 0 position
CH temperature selector to 0 position
DHW temperature selector to 0 position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Observation:
Reset lock out as necessary.
Allow appliance to self check and go to standby mode.
Sparking should occur approximately 2 to 5 seconds after the DHW temperature selector is turned on.
DHW temperature selector to maximum position.
Does sparking occur between the spark electrodes.
Allow appliance to self check and go to standby mode.
Sparking should occur approximately 2 to 5 seconds after the DHW temperature selector is turned on.
DHW temperature selector to maximum position.
Does sparking occur between the spark electrodes.