Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
CH temperature selector to 0 position
DHW temperature selector 0 position
DHW temperature selector 0 position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Observation:
Reset lockout as necessary.
Allow appliance to return to standby mode
DHW temperature selector to maximum position
With a flow rate at the hot tap of approximately 10.2 litres/minute is there a temperature rise of approximately 35°C
Allow appliance to return to standby mode
DHW temperature selector to maximum position
With a flow rate at the hot tap of approximately 10.2 litres/minute is there a temperature rise of approximately 35°C