Set Appliance State:

Mains Power Off
Set Multimeter to DC Volts Set meter to measure DC Volts
DHW temperature selector to 0 position
CH temperature selector to 0 position
Lower control box cover
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

All heating controls calling.
Measure voltage across the CH 24 volt input control terminal and the main neutral on the PCB.
Expected voltage between 22 and 40 volts DC.
Note:
The input of the 24 volt connector is the upper of terminals on the connector.