Set Appliance State:
Gas Off
Isolate Mains Power to appliance as per TOPs P4
Observation:
All external controls should be wired together in series and connected 'voltage free' across J2-4 and J2-5.
Check there is one wire connected to J2-4 and one wire connected to J2-5.
NOTE!
If External Controls are present and are wired in accordance with the above instructions, the red link MUST have previously been removed.
The Red Link as shown in the diagram should only be in place if no External Controls are fitted.
Check there is one wire connected to J2-4 and one wire connected to J2-5.
NOTE!
If External Controls are present and are wired in accordance with the above instructions, the red link MUST have previously been removed.
The Red Link as shown in the diagram should only be in place if no External Controls are fitted.
Isolate as per TOPs P4
and refit as necessary