GREY SOLENOID VOLTAGE
Set Appliance State:
Mains Power Off
Set Multimeter to DC Volts
CH Demand
WARNING!
Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On
Measurement:
Measure DC voltage across the connector on the grey solenoid.
VOLTAGE GREATER THAN 18V DC
VOLTAGE LESS THAN 18V DC
After test don't forget
Isolate as per TOPs P4
and refit as necessary
Isolate as per TOPs P4