Set Appliance State:

Set Multimeter to Resistance Set meter to measure resistance
Isolate Mains Power to appliance as per TOPs P4
Disconnect grey wires (1) of 110°C high limit thermostat
on right hand side of boiler
Note:
The grey wires of the 110°C high limit thermostat are connected to two black wires (2) via male and female
spade connections

Measurement:

Measure resistance of 110°C high limit thermostat
(auto reset) across disconnected grey wires.
Reconnect wires after measurement.